INSTALLATION
Alignment
ANCHORING
Adjust the depth of the unit to fit flush with surrounding
cabinetry. Once aligned, verify doors and drawers open
properly, then install screws in each side trim.
SCREW
SIDE TRIM
CABINETRY
FACE
FRAME
PANEL
FRONT OF
THICKNESS
UNIT
Anchoring
|
6
English
Water Line
Purge the water line prior to final connection to the unit. This
will remove any debris that may be present in the tubing
from installing the new water line. Connect the plastic tubing
from the unit to the house water supply line with the fitting
connection kit provided. Check all water line fittings for
leaks.
Locate the water line in the notch as shown in the illustration
below.
IMPORTANT NOTE:
Water lines can not be exposed to
freezing temperatures.
NOTCH
WATER LINE
CONNECTION
Water line.
PANELS
Stainless Steel Panels
The outdoor model requires the use of Sub-Zero stainless
steel outdoor accessory panels. Stainless steel panels are
available through an authorized Sub-Zero dealer.
The thickness of indoor stainless steel panels is 19 mm
and outdoor stainless steel panels are 38 mm. The depth of
each integrated model is 610 mm. Allow for panel thickness
when planning the finished opening depth.
3 mm reveals are typical, however, the reveal between the
upper and lower outdoor stainless steel panels is 6 mm to
accommodate the lock.
Custom Panels
For integrated models, custom door panels and handle
hardware must be installed.
The thickness of the custom panel can vary. A minimum
16 mm thick panel is required, but the thickness can be
increased provided it does not exceed the maximum panel
weight indicated in the chart below. The depth of each
integrated model is 610 mm. Allow for panel thickness when
planning the finished opening depth.
PANEL REQUIREMENTS
COLUMN
MAX WEIGHT
457 mm Models
610 mm Models
762 / 914 mm Models
TALL (DOOR)
MAX WEIGHT
762 mm Models
914 mm Models
DRAWER
MAX WEIGHT
All Drawer Panels
PANEL THICKNESS
MINIMUM
All Panels
Reveals between panels can vary, 3 mm reveals are typical.
CAUTION
When installing a panel thicker than 25 mm, the 90°
stop may be required to prevent damage to the unit
and adjacent cabinetry.
CAUTION
As reveals between cabinetry and the unit decrease,
severe finger pinching can occur while door is closing.
Finish all sides of custom panels. They will be visible when
the door is open.
D-style handles are recommended. Stainless steel tubular
and pro handles are avail able through an authorized
Sub-Zero dealer. Door handles must be located near the
edge of the panel opposite the hinge and should be cen-
tered top to bottom. Drawer handles must be located near
the top edge of each panel.
20 kg
27 kg
34 kg
22 kg
27 kg
7 kg
16