IMPORTANT SAFETY INSTRUCTIONS
20. DO NOT DRIVE FASTNERS too close to the edge of the workpiece. The
workpiece is likely to split, allowing the fasteners to fly free or ricochet
causing personal injury.
21. STAY ALERT. Keep hands and body away from the path of any potential
fired fastener. Watch what you are doing & use common sense. Do not
operate any tool when you are tired.
22. GUARD AGAINST ELECTRIC SHOCK. Prevent body contact with
grounded surfaces: pipes, radiators, ranges, and refrigerator enclosures.
Before driving fasteners into walls, floors, or wherever "live" electrical
wires may be encountered, try to ascertain whether there is a danger of shock.
23. KEEP WORK AREA CLEAR of obstructions.
24. EMPLOYERS must enforce compliance with the safety warnings and
all other instructions in this manual. Keep it available for use by everyone
assigned to use this tool.
SPECIFICATIONS
2" BRAD NAILER
= Shoots industry standard 18 gauge brad nails in the following sizes: 15 mm
(5/8"), 20 mm (3/4"), 25 mm (1"), 30 mm (1-3/16"), 35 mm (1-3/8"), 40 mm (1-
9/16"), 45 mm (1-3/4"), and 50 mm (2").
= These brads are perfect for installing trim and mouldings, for cabinet and fur-
niture making, picture framing, and for applications where gluing is necessary,
but clamping is impractical.
= Air consumption is 2 – 4 cfm / 57-113 litres per min @ 414-621 kPa /
60 to 90 psi.
= Quick-release nose piece.
= Padded hand grip.
= Adjustable exhaust deflector
= Air inlet: 1/4" NPT
= Included:
= S3 hex key
= S4 hex key
= Small bottle of air tool oil
= Tool weight: 3.3 lb / 1.5 kg
SETUP & OPERATION

AIR SYSTEM

= The brad nailer is designed to operate on clean, dry, compressed air, regulated
at 60-100 psi / 413 to 690 kPa / 4.13 to 6.9 bar. The preferred system would
include a filter, a pressure regulator, and an automatic oiler located as close to
the tool as possible (within 15 feet / 5 meters is ideal). Do not use bottled air
or gases. Please see figure below:
Oiler
Air Hose
Filter
Regulator
Air Supply