- As soon as "H2O" disappears from the control
panel, set to "OFF" and add salt (non-iodised
cooking salt).
The amount of salt required for
correct operation should be calculated according
to temperature and to the amount of water being
used. See the technical data sheet for the pool for
more information about water content and the table
listing solution concentrations.
- Prepare the ACID solution to put in the pool: make
a mix of 600g pH minus in 3 litres of mains water;
top up the tank.
Wait 2 hours before starting the TREAT.
In the meantime, use the strip to check the water
values.
Adjust alkali levels: if high (> 120 mg/l), using
CALCINEX (add 25 ml at a time, switch on the
hydro and after 10 minutes, check the value) – We
recommend repeating the operation as necessary,
when the alkali level is high (recommended range
80-150 ppm CaCO3) or when the water is cloudy.
If pH > 8.5 add a small amount of pH minus (10g at
a time, waiting for it to dissolve completely), directly
to the pool by hand so as to lower the pH to 8.
-
2
hours
after
adding
hyperchlorination, setting the automatic treatment
in manual mode.
This operation is recommended every time
that water is changed or as needed (after a day
of intensive use where the pool has not been
accessible, or if the water should turn green).
After 20 minutes, the TREAT will automatically set
itself to AUTO and continue to monitor the chlorine
parameters and the pH of the water.
AUTOMATIC WATER TREATMENT
Water tempera-
salt,
carry
out
Salt content
ture °C
< 25
25 ÷ 30
>30
15sec.
EN
g/litre
8
6
4
15sec.
15sec.
15sec.
5