Télécharger Imprimer la page
Leviton Decora 6651 Directives D'installation
Leviton Decora 6651 Directives D'installation

Leviton Decora 6651 Directives D'installation

Publicité

Liens rapides

C O L L E C T I O N B Y L E V I T O N
Timer Light Switch
Lighting control is a primary consideration for both residential and commercial interior design. Also, energy conservation has become a major issue for many
applications. The Leviton Decora line of lighting controls are designed with these ideas in mind. Some applications include indoor and outdoor lighting, office
Cat. No. 6651
lights, etc. Energy is saved with these Timers since lights or other types of loads will shut OFF automatically according to the setting on the Timer.
INSTALLATION INSTRUCTIONS
Ratings:
500W-120VAC, 60Hz Incandescent Only
Interrupteur-minuterie
Nº de cat. 6651
• This device is not intended for use on electronic ballasts.
DIRECTIVES D'INSTALLATION
• This device is suitable for single-pole or 3-way applications.
• Installing this device requires experience with residential and commercial wiring practices. Confirm that all circuit wiring complies with local codes and
ordinances. Failure to follow instructions exactly may permanently damage the unit, expose you to dangerous voltages and void all warranties stated
Interruptor de Luz con Cronómetro
and/or implied.
No. de Cat. 6651
• The Timer's memory is protected by correctly installed batteries. The Timer will continue to operate for up to 48 hours in the event of a power failure.
INSTRUCCIONES DE INSTALACIÓN
When power is restored, the Timer will operate automatically in accordance with the preset time schedule. The Timer can operate without batteries
when power is ON.
Function slide switch: Located below the Timer's touch pad. Controls OFF, manual, and auto modes.
OFF: Power to the switch and the Timer is disconnected when the Timer is set to the OFF mode.
MAN: In the MAN (manual) mode the switch is powered. ON/OFF switching can be controlled by pressing the lower
DI-000-06651-20C
half of the Timer touch pad.
AUTO: In this mode, the Timer follows the programmed switching cycle according to the preset instructions
(see "Operation") .
LIMITED TWO YEAR WARRANTY AND EXCLUSIONS
LED: A Green LED glows above the Timer touch pad while in the AUTO mode. Program status may be overridden
Leviton warrants to the original consumer purchaser and not for the
benefit of anyone else that this product at the time of its sale by Leviton
manually within the current hourly increment by pressing the Timer touch pad.
is free of normal and proper use for two years from the purchase date.
Leviton's only obligation is to correct such defects by repair or
replacement, at its option, if within such two year period the product is
returned prepaid, with proof of purchase date, and a description of the
WARNING:
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
2591. This warranty excludes and there is disclaimed liability for labor
for removal of this product or reinstallation. This warranty is void if this
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
product is installed improperly or in an improper environment, overloaded,
WARNING:
TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A
misused, opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels or
RECEPTACLE, FLOURESCENT LIGHTING, A MOTOR, OR A TRANSFORMER OPERATED APPLIANCE.
instructions. There are no other or implied warranties of any kind,
CAUTION:
including merchantability and fitness for a particular purpose, but if any
USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL.
implied warranty is required by the applicable jurisdiction, the duration
1. TURN OFF POWER.
of any such implied warranty, including merchantability and fitness for a
particular purpose, is limited to two years. Leviton is not liable for
2. Remove insulation from circuit conductors to expose 3/4" (1.9 cm) bare copper.
incidental, indirect, special, or consequential damages, including without
3. Remove pre-cut insulation sleeves on each Timer switch lead to expose bare wire strands.
limitation, damage to, or loss of use of, any equipment, lost sales or
profits or delay or failure to perform this warranty obligation. The remedies
4. Single Pole Installation (Dia. 1): Disconnect circuit conductors from existing single-pole switch and remove old switch, if applicable. Insulate end of
provided herein are the exclusive remedies under this warranty, whether
Yellow lead. Proceed to step #5.
based on contract, tort or otherwise.
3-Way Installation (Dia. 2):
For Technical Assistance Call:
NOTE: Only one traveler is required for 3-Way application.
1-800-824-3005 (U.S.A. Only)
www.leviton.com
Disconnect circuit conductors from one of the existing 3-way switches and remove old switch, if applicable. Connect conductor from the 3-Way switch
common terminal (usually Black screw) to Yellow lead. Connect (1) traveler conductor (from Brass screw on the 3-Way switch) and the conductor from
the lamp's center contact to the Blue lead. Insulate unused traveler in the wall box with the Timer. Disconnect and insulate unused traveler in the
wallbox switch with the 3-Way switch.
5. Connect wires per appropriate WIRING DIAGRAM as follows: Twist strands of each separate wire tightly together with circuit conductor and push firmly
into appropriate wire connector. Screw connectors on clockwise making sure that no bare copper shows below the wire connectors. Secure each wire
connector with electrical tape.
EXCLUSIONS ET GARANTIE LIMITÉE DE 2 ANS
Leviton garantit au premier acheteur, et uniquement au crédit du dit acheteur,
6. Mount device "TOP" up using screws provided. Attach wallplate.
que ce produit ne présente ni défauts de fabrication ni défauts de matériaux
7. Slide function switch to OFF position.
au moment de sa vente par Leviton, et n'en présentera pas tant qu'il est
utilisé de façon normale et adéquate, pendant une période de 2 ans suivant
8. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE.
la date d'achat. La seule obligation de Leviton sera de corriger les dits défauts
en réparant ou en remplaçant le produit défectueux si ce dernier est retourné
port payé, accompagné d'une preuve de la date d'achat, avant la fin de la
dite période de 2 ans, à la Manufacture Leviton du Canada Limitée, au
1. Remove the Timer's touch pad using a small blade screwdriver, nail file, pen knife or similar object. Insert it into the space located at the bottom of the
soin du service de l'Assurance Qualité, 165, Boul. Hymus Blvd., Pointe-
touch pad cover and lift up.
Claire, Québec Canada, H9R 1E9. Par cette garantie, Leviton exclut et
décline toute responsabilité envers les frais de main d'oeuvre encourus
2. The 14 numbered DIP switches should be visible. Each switch has an ON (right) and OFF (left) position representing one-hour time
pour retirer et réinstaller le produit. Cette garantie sera nulle et non avenue
segments (Fig. 2). Counting begins when the function switch is moved from the OFF position.
si le produit est installé incorrectement ou dans un environnement inadéquat,
s'il a été surchargé, incorrectement utilisé, ouvert, employé de façon abusive
3. Schedule a switching program (up to 14 hours) by moving each DIP switch into an ON or OFF position, starting with switch 1 located
ou modifié de quelle que manière que ce soit, ou s'il n'a été utilisé ni dans
at the bottom of the row (Fig. 2).
des conditions normales ni conformément aux directives ou étiquettes qui
l'accompagnent. Aucune autre garantie, explicite ou implicite, y compris
FOR EXAMPLE: If the lights are desired to turn ON for 3 hours, OFF for 4 hours and ON again for 3 hours, set the switches as follows:
celle de qualité marchande et de conformité au besoin, n'est donnée, mais
Slide DIP switches 1 thru 3 to the ON position, 4 thru 7 to the OFF position, 8-10 to the ON position, and 11 thru 14 to the OFF position (Fig. 2).
si une garantie implicite est requise en vertu de lois applicables, la dite
4. The Timer will respond automatically to the programmed instructions every 60 minutes when the function switch is in the AUTO mode.
garantie implicite, y compris la garantie de qualité marchande et de
conformité au besoin, est limitée à une durée de 2 ans. Leviton décline toute
At the end of the 14 hour program, the Timer will turn the light OFF until the original start time is reached after 24 hours. The switch
responsabilité envers les dommages indirects, particuliers ou consécutifs,
will continue to operate in this manner until the function switch is moved to the MAN or OFF modes.
incluant, sans restriction, la perte d'usage d'équipement, la perte de ventes ou
NOTES:
les manques à gagner, et tout dommage-intérêt découlant du délai ou du défaut
de l'exécution des obligations de cette garantie. Seuls les recours stipulés dans
• To activate the program (on the first day only), the function switch should be set to the OFF position for two seconds, then set to the
les présentes, qu'ils soient d'ordre contractuel, délictuel ou autre, sont offerts
AUTO mode to begin the programmed switching cycle.
en vertu de cette garantie.
• If the function switch is in the MAN mode at the time the program is desired to start, switching to AUTO without first switching to OFF,
Pour toute aide technique, composer le:
will resume the AUTO function for the remainder of the previous program start time.
1 800 405-5320 (Canada seulement)
www.leviton.com
DI-000-06651-20C
DI-000-06651-20C
1
ENGLISH
DESCRIPTION
SPECIFICATIONS
GENERAL INFORMATION
Fig. 1 - Characteristics
FEATURES (FIG. 1)
Touch Pad
Cover
Function
Settings
Function
Switch
TO INSTALL
OPERATION
Batteries should be replaced every 12 - 18 months, more frequently in areas where power interruptions are common.
1. TURN OFF POWER.
2. Use a small blade screwdriver, nail file, pen knife or similar object to remove the Timer's touch pad.
3. Using the same tool, gently pry off the battery cover plate. Replace the batteries "+" side facing up.
4. Push battery cover firmly back into place and replace touch pad.
5. Restart the Timer after battery replacement. Refer to "Operation" section.
La commande de l'éclairage est un aspect fort important à considérer lors de l'aménagement d'un décor, qu'il soit résidentiel ou commercial. De plus, la
conception des applications d'aujourd'hui est de plus en plus axée sur l'économie de l'énergie. Conçues pour répondre à ces critères, les commandes
d'éclairage de la gamme Decora de Leviton sont offertes pour commander l'éclairage extérieur, intérieur, de bureau, etc. Ces interrupteurs permettent
d'économiser l'énergie en éteignant automatiquement les charges leur étant raccordées selon les réglages programmés.
Valeurs nominales :
500W-120 V c.a., 60 Hz au incandescence seulement.
Battery
• Ce dispositif n'est pas conçu pour les ballasts électroniques.
LED
Compartment
Cover
• Ce dispositif convient aux applications unipolaires ou à trois voies.
• L'installation de ce dispositif requiert une certaine expérience en câblage électrique résidentiel et commercial. S'assurer que ce câblage soit conforme
Battery
aux codes de l'électricité en vigueur. À défaut de se conformer aux présentes directives, on risque d'endommager le dispositif, de s'exposer à de
ON
Compartment
14
dangereuses tensions, ou d'annuler toute garantie, explicite ou implicite.
13
12
DIP Switches
11
10
9
8
• La mémoire de cet interrupteur est protégée par des piles (s'assurer qu'elles soient insérées correctement). Si une panne d'électricité survient, le
7
6
5
dispositif peut continuer de fonctionner pendant 48 heures; une fois le courant rétabli, l'interrupteur continue de fonctionner selon sa programmation.
AUTO
4
3
MAN
2
1
Wallplate
Ce dispositif ne requiert pas de piles pour fonctionner lorsque le circuit est sous tension.
OFF
CARACTÉRISTIQUES (ill.1)
Bouton de fonction : situé sous la touche de l'interrupteur, ce bouton permet de sélectionner trois modes de
fonctionnement : mise hors tension (OFF), mode manuel ou mode automatique.
Mise hors tension : lorsque le bouton et réglé à cette position, l'alimentation à l'interrupteur est coupée.
Mode manuel : réglé à cette position, l'interrupteur est alimenté et peut être utilisé pour effectuer la commande manuelle à
partir de sa touche.
Mode automatique : réglé à cette position, l'interrupteur fonctionne selon les cycles de commutation préréglés (se
reporter aux directives décrites à la section (Fonctionnement»).
Témoin: un témoin Vert s'allume au-dessus de la touche en mode automatique (on peut outrepasser la
programmation de la tranche horaire en cours en appuyant sur la touche).
AVERTISSEMENT :
INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L'ÉLECTRICITÉ EN VIGUEUR.
AVERTISSEMENT :
À DÉFAUT DE BIEN COMPRENDRE LES PRÉSENTES DIRECTIVES, EN TOUT OU EN PARTIE, ON DOIT FAIRE APPEL À UN
ÉLECTRICIEN QUALIFIÉ.
AVERTISSEMENT :
POUR ÉVITER LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU D'ÉLECTROCUTION, COUPER LE COURANT AU
FUSIBLE OU AU DISJONCTEUR ET S'ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À L'INSTALLATION.
AVERTISSEMENT :
POUR ÉVITER LA SURCHAUFFE OU L'ENDOMMAGEMENT ÉVENTUEL DE CE DISPOSITIF ET DES APPAREILS QUI LUI
SONT RACCORDÉS, NE PAS L'INSTALLER POUR COMMANDER UNE PRISE, UN LUMINAIRE FLUORESCENT, OU UN APPAREIL MOTORISÉ OU À
TRANSFORMATEUR.
MISE EN GARDE :
N'UTILISER CE DISPOSITIF QU'AVEC DU FIL DE CUIVRE; EN PRÉSENCE DE FIL D'ALUMINIUM, UTILISER SEULEMENT LES
DISPOSITIFS PORTANT LA MARQUE CU/AL OU CO/ALR.
1. COUPER LE COURANT.
2. Dénuder les fils du circuit sur environ 1,9 cm (3/4 po).
3. Retirer la gaine isolante pré-entaillée des fils de l'interrupteur de manière à exposer les brins de cuivre.
4. Application unipolaire (sch. 1) : le cas échéant, défaire les raccords de l'interrupteur existant et dénuder les fils du circuit. Couvrir le fil Jaune d'un serrefil.
Passer à l'étape 5.
Application à trois voies (sch. 2) :
REMARQUE : l'installation sur un circuit à trois voies requiert un seul fil itinèrant.
Le cas échéant, défaire les raccords d'un des deux interrupteurs existants et le retirer. Raccorder le conducteur de la borne commune (habituellement noire) de
l'interrupteur à trois voies au fil de sortie jaune. Raccorder l'un des fils itinérants (borne laiton de l'interrupteur à trois voies) et le conducteur du contact central
de la lampe au fil de sortie bleu. Isoler le fil itinérant inutilisé dans la boîte de l'interrupteur-minuterie.
Fig. 2
Défairer et isoler le fil itinérant inutilisé dans boîte de l'interrupteur à trois voies.
DIP Settings
5. Raccorder les fils conformément au schéma de câblage approprié et de la façon suivante : Torsader solidement ensemble les brins de
ON
tchaque connexion et enfoncer fermement le raccord dans un serre-fils de calibre approprié, en tournant ce dernier vers la droite et en
s'assurant qu'aucun brin de cuivre ne soit exposé. Protéger les raccords au moyen de ruban isolant. Couvrir tout fil inutilisé d'une marret.
14
13
6. Fixer le dispositif au moyen des vis fournies en prenant soin d'orienter la marque "TOP" vers le haut. Fixer la plaque murale.
12
11
7. Régler le bouton de fonction à la position hors tension (OFF).
10
9
8. Rétablir le courant au fusible ou au disjoncteur; L'INSTALLATION EST TERMINÉE.
8
7
6
5
1. Retirer la touche de l'interrupteur au moyen d'un petit tournevis, d'une lime à ongle, d'un couteau de poche ou d'un autre objet de ce type
4
en en insérant la pointe dans la fente située au bas de la touche et en soulevant cette dernière.
3
2
2. Une fois la plaque retirée, on trouve les 14 commutateurs «DIP». Chacun d'eux représente une heure et peut être déplacé vers la droite
1
(sous tension) ou vers la gauche (hors tension). Pour activer la minuterie, déplacer le bouton de fonction vers la droite (ON) (se reporter à l'Ill. 2).
7/19/01, 10:50 AM
BATTERY REPLACEMENT
FRANÇAIS
DESCRIPTION
FICHE TECHNIQUE
RENSEIGNEMENTS GÉNÉRAUX
ill. 1 - Caractéristiques
Touche
ON
14
13
12
11
10
9
8
7
6
5
AUTO
4
3
MAN
2
1
OFF
Programación
de Función
Interruptor
de Función
INSTALLATION
FONCTIONNEMENT
Témoin
Couvercle du
compartiment
des piles
Compartiment
des piles
Commutateurs
<<DIP>>
Plaque
Murale
ill. 2
Commutateurs
<<DIP>>
ON
14
13
12
11
10
9
8
7
6
5
4
3
2
1

Publicité

loading

Sommaire des Matières pour Leviton Decora 6651

  • Page 1 3. Using the same tool, gently pry off the battery cover plate. Replace the batteries “+” side facing up. applications. The Leviton Decora line of lighting controls are designed with these ideas in mind. Some applications include indoor and outdoor lighting, office Cat.
  • Page 2 El control de iluminación es una consideración primaria en el diseño de interiores residenciales y comerciales. Además, el ahorro de energía es un asunto principal para muchas aplicaciones. La línea de controles de iluminación de Leviton Decora está diseñada con estas ideas en mente. Algunas aplicaciones incluyen iluminación interior y exterior, luces de 5.
  • Page 3 FOLD SCHEME 17.0¨ Front Panel Cat. No. 11.0¨ Front Panel Cat. No. Front Panel Cat. No. Fold Line Panel Line #'s = Fold Sequence DI-000-06651-20C 7/19/01, 10:50 AM...