The power supply allows 12Vdc units to be powered by the mains. It can supply the rated continuous
current over long periods of time and the peak current over a short period. The power supply features:
-
thermal protection
-
short-circuit protection
Safety Recommendations:
-
Check the housing and the connection lead for damages
-
For indoor use only
-
Do not use the unit in humid rooms
-
Do not let liquids penetrate the ventilation holes
-
Do not connect devices that need higher current outputs than those specified for the unit
-
Do not place the unit in warm locations (max. 30°C)
-
Do not obstruct the ventilation holes or heat sink. Leave enough space around the unit to ensure
sufficient ventilation
-
The heat sink becomes very hot during use. Do not touch it while in use !
-
Unplug the unit from the mains prior to replacing the fuse.
Operation:
-
Connect the unit to be powered to the red and black terminal
red
+
black -
-
The unit to be powered must not draw more current that the maximum continuous current output
of the power supply in order to prevent overload.
-
Do not operate the unit at full load for longer periods of time
-
Plug the power supply into a wall outlet.
-
Switch the unit on via the power switch. The power LED will light.
Protection:
If one of the built-in protection circuits is activated, proceed as follows:
-
Switch the power supply off
-
Let the power supply cool down if it is hot
-
Before you switch the power supply on again, check if the connected unit does not draw too much
current or is faulty.
-
Check the fuse when the power LED does not light up
Specifications:
All models:
Input voltage 230V / 50 Hz
Output voltage 13,8 Vdc
Model No.
Max Current
650.651
3 Amps
650.652
5 Amps
650.654
7 Amps
650.657
10 Amps
650.660
15 Amps
650.663
20 Amps
650.667
25 Amps
650.670
40 Amps
WARNING: Do not open the case. Risk of electrical shock. Repairs should only be carried out by a
qualified technician.
The Max Current can be supplied continuously for 30 min maximum.
Peak current
Weight
5 Amps
2,5 kg
7 Amps
2,8 kg
9 Amps
3,0 kg
12 Amps
3,5 kg
17 Amps
4,9 kg
22 Amps
8,0 kg
27 Amps
10,0 kg
42 Amps
18,0 kg