Installation Requirements; Tools And Parts; Location Requirements - Bauknecht GZ9736XSS Instructions D'installation Et Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill
⁵⁄₁₆" (8 mm) drill bits for pilot holes
⁵⁄₃₂" (4 mm) drill bits
Pencil
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Phillips screwdriver
Vent clamps
Metal snips
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculation) installations, you will also
need:
Charcoal Filter Kit Part Number 8212566
See "Assistance or Service" section to order.
5" (12.7 cm) diameter expandable/flexible aluminum duct
Vent clamps for a 6" (15.2 cm) diameter duct
Parts supplied
Remove parts from packages. Check that all parts are included.
Literature package
Decorative flue assembly
2 metal grease filters for 30" (76.2 cm) models
3 metal grease filters for 36" (91.4 cm) models
Parts bag containing:
Damper
Mounting bracket
Flue mounting bracket
8 drywall anchors
8 - 4.8 x 38 mm pan head mounting screws
6 - 3.9 x 9.5 mm pan head screws
2 - 3.9 x 5.7 mm flat head screws
4

INSTALLATION REQUIREMENTS

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The model/
serial rating plate is located behind the left filter on the rear wall of
the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance. Consult the cooktop/
range manufacturer installation instructions before making any
cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installations" in "Prepare Location" section.
Charcoal Filter Kit Part Number 4393848 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
8¹⁵⁄₁₆"
10¹⁵⁄₁₆"
(25.2 cm)
(27.8 cm)
30" (76.2 cm)
or
36" (91.4 cm)
7⁷⁄₈"
(20 cm)
32"
(81.3 cm) min.
46¹⁄₈"
(117.2 cm) max.
19¹⁄₁₆"
(48.4 cm)
5¹⁄₁₆"
(12.9 cm)
19⁵⁄₈"
(49.8 cm)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gz9736sss0

Table des Matières