►MODE:
-NORMAL:
ventilation speed in manual mode
between LOW, MID and HIGH.
-NATURAL: The ventilation speed of
the automatically switches between
LOW, MID and HIGH.
-SLEEP:
The
automatically remains at the set
speed for approximately 30 minutes,
then it automatically switches at
the lower speed for approximately
30 minutes and then automatically
switches to LOW speed. The LOW
speed remains set until the cooler
turns off.
►►4.3. SWITCHING OFF:
►4.3.1. Press the ON/OFF button to
switch off the appliance (Fig. 9).
►4.3.2. Empty the tank using the drain
cap (Fig. 10-11-12).
►►5. CLEANING AND
MAINTENANCE
WARNING: BEFORE PERFORMING
ANY MAINTENANCE OR REPAIR,
DISCONNECT THE POWER CABLE
FROM THE MAINS.
DEPENDING ON THE ENVIRONMENT
WHERE THE APPLIANCE IS USED,
DUST, DIRT OR WATER QUALITY CAN
AFFECT THE PERFORMANCE OF
THE UNIT. THEREFORE, CLEANING
THE FOLLOWING COMPONENTS
CAN BE NECESSARY:
►►5.1. TANK:
We recommend changing the water
frequently.
►5.1.1. Switch off the appliance and
disconnect the plug from the mains
(Fig. 9-6).
►5.1.2. Remove the drain plug and
empty the vessel, then wash it, using
Figures and texts of this book are protected by COPYRIGHT.
Allows
setting
ventilation
speed
a soft cloth. Wash away the dirt from
the
the water sensor, water pump and
float valve. Rinse everything.
►5.1.3. In order to clean the housing,
use delicate soap and a soft cloth. Do
not use any caustic detergents, which
may damage the air conditioner
housing.
►5.1.4. In order to prevent the
accumulation of algae and other
biological organisms in the vessel,
add chlorine or bromine tablets or
other tablets recommended by the
manufacturer
for the vessels of evaporation air
conditioners.
►►5.2. FILTERS:
It is recommended to clean the filters
frequently.
WARNING: Dirty filters can lead to
a significant drop in performance
of the device.
►5.2.1. Turn off the device and
disconnect the plug from the power
mains (Fig. 9-6).
►5.2.2. Remove the filter (Fig. 13).
►5.2.3. Clean the filter with a mild
detergent and a clean cloth (Fig. 14).
Make sure that the filter is perfectly
dry.
►5.2.4. Reassemble the filter (Fig.
15).
►►5.3. WATER CIRCUIT:
►5.3.1. To ensure proper operation of
the cooler, turn off COOL mode a few
minutes before completely switching
off the appliance, in order to avoid
stagnant water.
►5.3.2. Once a month we recommend
performing
using clean water and appropriate
disinfection products, running the
cooler outdoors.
regularly,
intended
a
complete
cycle