5. START-UP
•
FIRST CLEANNING
Clean the unit before connecting to the electricity supply.
•
INSPECTION
•
Check that the voltage and power line frequency coincide with those indicated on the specification plate of the appliance.
•
The unit should not be used in threatening atmospheric or fire risk conditions.
•
Check that there are no defects on the unit resulting from its transportation. The manufacturer will not be liable for damage
suffered during transportation or arising from incorrect storage.
•
Check the operation of the moving components of the unit.
•
Check the safety of the control board, electrical cables and connections.
•
Check that all the interior and additional accessories are present.
•
GENERAL CONNECTIONS
•
Be sure the power cable is not damaged.
•
If the power cable is damaged it must be replaced by another type H05-VV-F or H05-VVH2-F. Thisrepairmust be
performedbyqualifiedpersonnel.
•
It is essential that the electrical installation to which the unit is going to be connected has an EARTH LEAD, as well as the
necessary thermal and differential magnetic protection.
•
The power supply must have the suitable section for the consumption of the appliance.
•
If various units are installed in a row, each one must be connected independently to the power supply, avoiding the use of
extension leads or multiple plugs.
•
The manufacture disclaims all liability in the event that any of the above points are not followed.
•
OPERATING ELEMENTS AND INDICATORS
THERMOSTAT
The environmental operational limits established for the units are shown by climatic category:
Climatecategory
0
1
2
3
4
6
7
8
6. RECOMMENDATIONS
•
In order to obtain better performance, avoid the introduction of hot foods as well as drinks that are not in sealed packages.
•
Protect foods and their odours by using some hermetic closing system, placing them in the unit in such a way that allows for a
good circulation of air, respecting the maximum load indicated on the inside of the unit.
• One the inside of the unit is clean, connect the power supply and place the switch
in the I/ON position. The switch should be lit up.
• Adjust the thermostat. (recommended position No. 6)
RelativeHumidity
DrybulbtemperatureºC
20
16
22
25
30
27
35
23.9
Dewpoint
%
ºC
50
9.3
80
12.6
65
15.2
60
16.7
55
20.0
70
21.1
75
30.0
55
14.3
Mass of water
vapor in dry
airg/kg
7.3
9.1
10.8
12.0
14.8
15.8
27.3
10.2