10. AQUATIMER A3000 open – without ECC
Materials required
Customer to provide:
• Wetroom distributor box (≥100 mm × ≥100 mm)
• Residual current safety device (RCD)
• Empty ducting for connection cable bypass solenoid valve
= at least 20 mm)
inner
• Empty ducting for cable
• flexible 2-core cable (type H05VV-F 2×0.75 mm²; for max. 24 fittings over a max.
length of 100 m)
• Empty ducting for system cable
Accessories
Mains unit - A3000 open (12 W)
230 V AC / 24 V DC . . . . . . . . . . . 2000100375
Key-operated switch . . . . . . . . . . . 2000102675
Bypass solenoid valve cartridge . . 2000100431
Connection cable
for bypass solenoid valve. . . . . . . 2000100432
Preparing the electrical connection
Place the power supply and the key-operated switch outside the wetroom in a
separate room and protect with a residual current safety device (RCD).
10.1 Install one wetroom distributor box (a) per shower.
10.2 Lay an empty duct (c; Ø
the shower.
10.3 Lay a flexible 2-core cable (b) in the empty duct and loop from wetroom distributor
box to wetroom distributor box.
10.4 Push the connection cable (d) for the bypass solenoid valve through the empty duct (c).
The plug must be easily accessible in the shower.
10.5 Connect the connection cable (d) for the bypass solenoid valve in the wetroom
distributor box.
10.6 Close off the wetroom distributor box with the protection cap (e).
Order No.
= at least 20 mm) from the wetroom distributor box to
inner