Technical data
Type
Power supply
Power consumption
Nominal force
Nominal locking force
Service life
Duty cycle
Housing
Ingress protection
Temp. range
Emission sound pressure level
Nominal stroke length*
Additional functions
* Adjustable with magnet
Running speed and forces
All forces + approx. 20 % switch-off reserve (temporary)
Closing edge protection
In the "CLOSE" direction the drive set has an active
protection for the main closing edge. If there is an
overload in the closing ranges 3 and 2, the drives run
"OPEN" for 20 seconds, then "CLOSE" again. If
closing is not possible after three attempts, the
drives remain in this position.
In addition, the drives are equipped with passive
protection. The closing speed in closing range 2 and
1 is reduced to 5 mm/s.
Significantly greater forces can be
exerted at the secondary closing edges.
Danger of crushing hands and fingers!
6/16
VCD 204 -K
VCD 204 -K-TMS+ Set
230 V AC / +10...-15 % / 50 ... 60 Hz
22 W / 30 VA
2x 200 N
approx. 2x 2000 N (Excluding bracket)
>20 000 double strokes
30 % (With cycle time 10 minutes)
Zinc-diecasting, powdercoated
IP 30
0 ... +60 °C
LpA ≤ 46 dB(A)
See type plate
Closing edge protection activated (3 stroke repeatings),
Locking relief activted
English
99.831.12 1.2/01/19