3.5 Configuration of the controller
Fully programmable charge algorithm (see the sof tware page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Pos
Suggested battery type
Gel Victron long lif e (OPzV)
0
Gel exide A600 (OPzV)
Gel MK
Gel Victron deep discharge
Gel Exide A200
1
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (f looded)
Rolls Solar (f looded)
Default setting
Gel Victron deep discharge
Gel Exide A200
2
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (f looded)
Rolls Solar (f looded)
AGM spiral cell
3
Stationary tubular plate (OPzS)
Rolls AGM
PzS tubular plate traction
4
batteries or
OPzS batteries
PzS tubular plate traction
5
batteries or
OPzS batteries
PzS tubular plate traction
6
batteries or
OPzS batteries
Lithium Iron Phosphate
7
(LiFePo
) batteries
4
Note: div ide all v alues by two in case of a 12V sy stem and
multiply by two in case of a 48V sy stem.
6
Absorption
Float
V
V
28,2
27,6
28,6
27,6
28,8
27,6
29,4
27,6
29,8
27,6
30,2
27,6
30,6
27,6
28,4
27,0
Equalize
dV/dT
V
mV/°C
@%I
nom
31,8
-32
@8%
32,2
-32
@8%
32,4
-32
@8%
33,0
-32
@8%
33,4
-32
@25%
33,8
-32
@25%
34,2
-32
@25%
n.a.
0