2.1 Programming parameters

Parameter name
Credit currency
P0.4
Base amount
P0.5
Accumulation
P0.6
of time
Start warning
P0.7
notice
Duration of
P0.8
warning notice
Volume of
P0.10 Indicate the volume of the internal buzzer: 0=OFF, 1=low, 2=medium, 3=high.
sound
System code
P0.11
Log file
Log
Base time
P1.2
Manual pause
P1.3
duration
Automatic
P1.4
pause start
Automatic
P1.5
pause duration
WARNING: only modify the parameter values which come after the "=" sign.

CONFIGURATION TABLE

Monetary value desired (EURO, EUR, €, USD, $, £, Coin, etc.).
Set the amount to deduct from the prepaid card.
If enabled, the duration of service will be prolonged and credit deducted by
placing the card near the reader area again.
Allows for the supplementary output to be used in order to warn that service is
about to end; the programmed time indicates the start of the warning notice for
end of service.
Set the duration of the automatic notice of end of service.
The system code allows you to protect the system from cards not belonging to
the same system. The system code programmed in the CT02 must be the same
as that memorized in the prepaid cards and in the CARDWRITER-01
programmer, otherwise the cards will be refused.
For more information, consult the instruction manual of the CARDWRITER-01
programmer.
If enabled, once the USB stick has been inserted into the CT02, a "CTLOG.TXT"
file will be created which contains a register of the total credit inserted in the
system.
Set the duration of service.
This is the time of the pause which can be utilized by the user of the service. It
can be divided into more than one period. If other than 0, the service
automatically starts in pause mode and is activatedat the end of the pause time
established or upon pressing the start/pause button.
For each service available a start/pause button can be connected to the CT02.
This is for activating a service or for placing a service in pause up to the
maximum time established.
It will be used as a delayed start for services which are not supplied with
start/pause buttons.
The automatic pause allows for the CT02 service to be interrupted for a certain
amount of time. It can be used as a warning notice for the end of service, or for
allowing time to lather in showers not supplied with start/pause buttons.
This parameter indicates the precise moment of activation of the automatic
pause before the service end time.
Set the duration of automatic pause.
Parameter description
Limits
Max 4 characters
Min=0000.00
Max=9999.99
0=NO
1=YES
Min=00m00s
Max=99m59s
Min=00m00s
Max=99m59s
Min=0
Max=3
Min=00000
Max=99999
0=NO
1=YES
Min=00h00m00s
Max=23h59m59s
Min=00m00s
Max=99m59s
Min=00m00s
Max=99m59s
Min=00m00s
Max=99m59s