Hotpoint Ariston PKL 641 D2/IX/HA Mode D'emploi page 21

Masquer les pouces Voir aussi pour PKL 641 D2/IX/HA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Burner and nozzle specifications (for 65 cm versions only)
Table 1
Burner
Diameter
(mm)
Reduced Rapid (RR)
100
Semi Rapid (S)
75
Auxiliary (A)
55
Double flame
36
(DCDR internal) (1)
(DCDR
Double
internal)
130
flame (1)
(DCDR
external
2 nozzle)
Supply pressures
(1) For single-control DRDA (DCDR) burner only
*
At 15°C and 1013,25 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
Burner and nozzle specifications (for 75 cm versions only)
Table 1
Burner
Diameter
(mm)
Reduced Rapid (RR)
100
Semi Rapid (S)
75
Auxiliary (A)
55
Double flame
36
(DCDR internal) (1)
(DCDR
Double
internal)
130
flame (1)
(DCDR
external
2 nozzle)
Supply pressures
(1) For single-control DRDA (DCDR) burner only
*
At 15°C and 1013,25 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/Kg
***
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
A
RR
DC
S
PKL 641 D2/IX/HA
PKL 642 D2/IX/HA
PKL 642 D2/IX/HAR
Liquid Gas
Thermal
Thermal
By-pass
power
power
1/100
kW
kW
(p.c.s.*)
(p.c.s.*)
Reduced
Nominal
(mm)
(mm)
0.70
2.60
39
0.40
1.65
28
0.40
1.00
28
0.30
0.90
29
29
1.50
3.60
57
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
Liquid Gas
Thermal
Thermal
By-pass
power
power
1/100
kW
kW
(p.c.s.*)
(p.c.s.*)
Reduced
Nominal
(mm)
0.70
2.60
39
0.40
1.65
28
0.40
1.00
28
0.30
0.90
29
29
1.50
4.20
57
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
RR
DC
A
PKL 751 D2/IX/HA
Nozzle
Flow*
Thermal
1/100
(g/h)
power
kW
(p.c.s.*)
***
**
Nominal
80
189
186
2.60
64
120
118
1.65
50
73
71
1.00
44
65
64
0.90
44
262
257
3.60
60x2
28-30
37
20
25
35
45
Nozzle
Flow*
Thermal
1/100
(g/h)
power
kW
(p.c.s.*)
(mm)
***
**
Nominal
80
189
186
2.60
64
120
118
1.65
50
73
71
1.00
44
65
64
0.90
44
305
300
4.20
67x2
28-30
37
20
25
35
45
S
S
Natural Gas
Nozzle
Flow*
1/100
(l/h)
(mm)
122(H3)
248
96(Z)
157
79(6)
95
74
86
74
343
94x2
20
17
25
Natural Gas
Nozzle
Flow*
1/100
(l/h)
(mm)
122(H3)
248
96(Z)
157
79(6)
95
74
86
74
400
100x2
20
17
25
GB
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pkl 642 d2/ix/haPkl 642 d2/ix/harPkl 751 d2/ix/ha

Table des Matières