Door Controller (Dc) - Fermax 4420 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH

Door Controller (DC)

The «Door Controller» (DC) lets you manage all the devices associated with an access,
increasing security and simplifying the installation of FERMAX centralised access control
systems (AC PLUS / MDS).
Status LEDs
Test pushbutton
Entry reader con-
nection
Door release connection
relay
The DC is able to control the following elements for a Door:

Entry reader and exit reader, one situated on the outside and the other on the inside (optional)
of the installation.
Maximun distance between Door Controller and Reader: 10 metres.

One exit pushbutton, that lets you open the door (pedestrian type) from inside the facility. In
vehicle doors, lets you connect an inductive loop presence sensor.

One Trades pushbutton (working hours), located on the outside of the facility, that allows the
door to open during a set schedule.

One 4/6 state door sensor. In vehicle doors, lets you connect an inductive validation loop.
If using the door sensor in 6 states mode, it is necessary to fi t the sensor with a10K resistance
in parallel and another 10K in series (See fi gure 1 in connections diagram).

Two relays. One of them may be used to control the door release, the other is used as an
auxiliary relay, and can be used to control an alarm associated to the door.
NOTE:
- Connecting
-
The VARISTOR is supplied with this controller, for 12 Vdc or 12 Vac door-openers.
-
If the system doesn't work properly (RESETS), connect the varistor in the controller between the
terminals to which the door-opener terminals are connected.
8
Bus connection
AC PLUS / MDS Central
TX RX
BUS
+
TEST
+
-
MADE IN SPAIN
DT
REF. 4420
CK
CONTROLADOR DE PUERTA
R
DOOR CONTROLLER
INPUT
G
12 V ; 100mA
BUZ
I N
LOCK
C
No
Nc C
Auxiliary relay
a VARISTOR in the door-opener (see connection diagram at the end of this manual).
Reader type and access nº
confi guration microswitch
ON
1 2 3
4
5
6
7
8
-
Sa Sb
CONFIG
BUS
BUZ
G
R
CK
DT
-
+
OUT
AUX
No Nc
BS
-
SP
TR
Exit reader connection
Door release connection, trades
and open door sensor

Publicité