Proceedment
Control Panel
The control panel is located below the doors on the front of the appliance.
Turn On
1. Close the door of the cabinet.
2. Connect it to a power supply.
3. First turn the light switch on to verify it is correct. The switch is located below the cabinet.
Adjust of the temperature
1. Press the set button for more than 2 seconds.
The value showed at the display indicates the set point.
At the same time the "Freezer icon"
2. Then to change the value push the arrow up or down buttons.
3. Press the "Set" button to save the temperature value. If you don't press it in 10 seconds the
value is stored automatically.
Storing Food
To get the best results from your appliance, follow these instructions:
• Only store foodstuffs in the appliance when it has reached the correct operating temperature.
• Do not place uncovered hot food or liquid inside the appliance.
• Wrap or cover food where possible.
• Do not obstruct the fans inside the appliance.
• Avoid opening the doors for prolonged periods of time.
Lock/Unlock the Doors
A lock is fitted to the doors to ensure foodstuffs are kept secure.
Use the keys provided to lock/unlock the door.
Maintenance
• Switch off and disconnect from the power supply before cleaning.
• Clean the interior of the appliance as often as possible.
• Do not use abrasive cleaning agents. These can leave harmful residues.
• Clean the door seal with water only.
• Always wipe dry after cleaning.
• Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
• A qualified technician must carry out repairs if required.
Defrost
To make the defrost manually, press the button
Cleaning the cold unit
Periodically cleaning the condenser can extend the life of the appliance.
It is recommended that a qualified technician clean the condenser.
Replace of Lamp
1) Allow the lamp to cool firstly, then change it to the new one.
2) Switch Off and disconnect the cabinet from the power supply
2) Loose the screws from the plastic lamp cover
3) Twist the lamp in its socket and release it from the socket
4) Remove the lamp and replace the new one of the same power rating