After three seconds, the display will show the actual air humidity; this will remain on the
display while the device is on.
Press on the 'humidity up or 'humidity down button in order to set the desired level. If the
set humidity is over 3% lower than the actual humidity level, the device will start to work
and continue until the actual level is 3% lower than the set level. The device will then
switch off.
If the air humidity is set to less than 30%, the device will continuously dehumidify. The
display will show "CO".
Press the ON/OFF button again in order to switch the device off. The device will come to a
halt and all of the lights will go out.
Note:
 If the set humidity is higher than the actual humidity, the device will not come on.
 If you are dehumidifying, the fan motor and the compressor will run for at least three
minutes before the compressor starts. The compressor may not be restarted within
three minutes of switching the device off. It is, therefore, possible that the motor will not
immediately respond to being turned off or on!
 When the temperature is low, keep an eye on whether the device needs to defrost.
When defrosting, the relevant light will come on and the fan will run but the compressor
will automatically switch off.
 The devices have an automatic memory that automatically stores the settings and also
saves if the power supply fails or is interrupted. Once the power supply has been
restored, the device will start to work according to the previously entered settings.
 The display will show a humidity level of 30% to 90%.
 Remove the plug from the socket if you do not plan to use the device for an extended
period.
 Only LO50: If the water reservoir is full, the light will come on and the compressor and
fan will automatically shut down. You will also hear a beep. If you do not drain the
reservoir, the beep will be repeated every 5 minutes. Only once the reservoir has been
emptied can the device be used again.
 Only LO50: You can install a continuous drain by removing the reservoir, taking the
rubber bung out of the base of the reservoir and connecting a hose to this outlet. Then
replace the reservoir and run the hose from the device (downwards) to a suitable
drainage point.
USE
 In order to avoid damaging the compressor, never place the dehumidifier on a slope of
over 45°.
 The device works between 5°C and 32°C.
 When being used, the compressor will emit heat which can increase the ambient
temperature by between 1 and 3°C. This is perfectly normal.
 If the indoor temperature is lower than 10°C and air humidity is pretty low, you will not
need to use the device.
 Ensure that there is at least 10 cm of free space between the air inlet and the outlet
opening and any solid objects, e.g. a wall.
 Try to ensure that the room is as well sealed as possible in order to improve the
dehumidification result.