Napoleon EF36H Guide D'installation Et D'operation page 18

Foyer électrique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8
- mobile home installation blurb
-
This fireplace is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
All other references to bedroom, etc type of installations should be removed.
16) This should appear in the framing sections following the statement "It is not necessary to install a hearth
extension with this fireplace system". The next line should be:
When roughing in the fireplace, raise the fireplace to accommodate for the thickness of the finished floor materials, i.e. tile,
carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and the installation of
many decorative flashing accessories.
17) standards:
Note from Cliff stating that sTANDArD for
z.88 and CsA .33
were just updated to
CsA .33-00 and ANsI z-88-00
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL
rating plates keep date but other literature does not.
sTANDArD for
DECOrATIvE
z.50-000 · CsA .-000
updated to
z.50a-00· CsA .a-00
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS,
18)
Change NAPOLEON LOGO under rEPLACEmENT PArTs
frOm:
W385-0033
TO:
W385-045
for CONTINENTAL usE
W385-03
19)
In all DIrECT vENT manuals, update venting graphs to look like GD36 W45-00.
20)
If already added, update massachusetts statement (see ) to:
Installation practices vary from region to region and it is important to know the specifics that apply to your area,
for example: in massachusetts state:
• The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert
• The appliance off valve must be a "T" handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
• WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of
massachusetts.
21)
22) Add Logo Placement Section from Leaflet into the manuals.
23) In ALL Vent Free manuals, in the VENTURI ADJUSTMENT section, after "...can lead to carboning *"
W45-0544 / 04.3.06
add:
WArNING: Carbon can be distributed in surrounding living area if the air shutter is improperly adjusted.
hEATErs:
STANDARDS, CSA 2.33, ANSI Z21.88 FOR vENTED gAS FIREpLACE hEATERS
fIrEPLACEs:
CSA 2.22, AND ANSI Z21.50 RESpECTIvELY FOR vENTED gAS FIREpLACES.
On the front page replace:
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
with:
or gas log.
sealed combustion
product.