additions/Changes Checklist
squares are black when they have been added to the manual,
(because they do not apply) and remain
manual.
1) Under Framing for all products which can be framed:
note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the
place body, it is recommended that the walls of the fireplace enclosure be "finished" (ie: drywall/sheetrock), as you would
finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.
2) Under - General Instructions : after....."to conform with local codes"........ - for all gas fireplaces :
all gas products:
Installation practices vary from region to region and it is important to know the specifics that apply to your area,
for example: in massachusetts state:
• The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert.
• The appliance off valve must be a "T" handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct-vent.
3) To all napoleon and Continental manuals:
) New Logos
) New e-mail and web addresses
ask@napoleon.on.ca
ask@continentalfire.com
3) Change street address from 9 to 4
4) To all manuals under "blower Installation".
Drywall dust will penetrate into blower bearings causing irrepairable damage and must be prevented from coming into contact
with the blower or its compartment.
Any damage resulting from this condition is not covered by the warranty policy.
5) Only Direct Vent Gas Fireplace
Under "InTRODUCTIOn" , "GEnERaL InsTRUCTIOns".
mobile home installation must conform with local codes. In the absence of local codes, install to the current standard for gas
equipped mobile housing CAN/CsA z40 mh series in Canada or the manufactured home construction and safety stand-
ard, Title 4 Cfr, part 380, or the fire safety Criteria for manufactured home installations, sites and Community standard
ANsI/NfPA 50A in the united states.
6) To all appropriate DV manuals which require W680-0005 and W680-0008 thermocouples. In the WaRn-
InG bOX in the front of these manuals:
"This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf
Steel Ltd."
also where these thermocouples are currently being used, W680-0005 and W680-0008.
"WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermo-
couple supplied by Wolf Steel Ltd."