SLV COLOR CONTROL SYSTEM Instructions D'utilisation page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
The standard distance of the system reaches up to 15 m in an open area depending on a surrounding
without disturbing effects (e.g. metal stud framing, reinforced concrete ceilings, other signals or similar).
The signal repeater allows to cover distances up to 30 m in an open area under ideal conditions. The
minimum distance between a slave unit and a master unit has to be at least 50 cm.
min. 50 cm
MASTER
SLAVE
max. 15 m
max.
15 m
Repeater
(470674)
max. 30 m
Status Indicator
The COLOR CONTROL Master Controller has a status indicator which displays the following modes
Blue: Regular operation status
Short white flash: new command executed
Long white flash: reaching mode or color cycle edge
Long yellow flash: reaching speed or brightness limit
Red flash: Overload protection active
Yellow flash: Overheat protection active
Setting up the zones
Setting up the zones is done after the complete installation and connection of all components of the
system. Before setting up the zones it is helpful to create a plan on the assignment of the components
to each zone. Setting up may start with any zone. Notice: When using the Color Control wall panel the
zones cannot be set up by the remote control.
1.
Turn on master unit and switch the slave units dead that are supposed to be assigned
to the zone. The slaves must be off power for at least 5 seconds.
Master
ON
W
Ma s te r
M O D E
S P E E D
Z O N E
A L L
1
2
3
Z O N E
Z O N E
Z O N E
WH I T E
WH I T E
O N L Y
O F F
Slave
OFF
COLOR CONTROL
Master Controller
(min. 5 sec.)
470671
SLAVE
W
W
A L L
M O D E
S P E E D
Z O N E
1
2
3
WH I TE
WH I TE
M O D E
SPEED
Z O N E
Z O N E
Z O N E
O N LY
O FF
LIPSY 36/50 M
O N L Y
WH I T E
WH I T E
O F F
1
2
3
A LL
ZO N E
ZO N E
ZO N E
ZO N E
Color Control (Master)
COLO Bulb
133749
COLOR CONTROL
470676
133759
Wall Panel
(
Master Stand-alone)
470670
2.
Turn on the slaves that are supposed to be assigned to the zone.
Slave
ON
Zone X
Slav e
(1,2,3)
COLOR CONTROL
Slave Controller
470672
3.
Within the next 5 seconds push the buttons Speed and White only simultaneously.
WHITE
(Combo-Key)
SPEED
ONLY
4.
Push the button of the zone that is set up for at least 5 seconds.
1
2
3
ZONE
ZONE
ZONE
The zone is now set up.
Start again with step 1 to set up the other zones.
Integrating the signal repeater
The signal repeater (470674) is utilized to reach a greater distance. The signal repeater is assigned to
one zone.
1.
Switch the signal repeater dead for at least 5 seconds. Turn on again afterwards.
2.
Within the next 5 seconds push the buttons Speed and White only simultaneously either on
the remote control or the wall panel.
3.
Push the button of the zone to which the signal repeater should be assigned.
Integrating additional remote controls
A master unit may be controlled by up to 5 remote controls. To assign an additional remote control
proceed with the following steps.
COLOR CONTROL
LIPSY 36/50 M
Color Control (Slave)
COLO Bulb
133748
470673
133758
(Sla ve)
W
W
WH I TE
WH I TE
M O D E
SPEED
M O D E
S P E E D
A L L
O N LY
O FF
Z O N E
1
2
3
Z O N E
Z O N E
Z O N E
A LL
1
2
3
WH I T E
WH I T E
ZO N E
ZO N E
ZO N E
O N L Y
O F F
ZO N E
W
W
WH I TE
WH I TE
M O D E
SPEE D
MO D E
S P E E D
A L L
Z O N E
O N LY
O FF
1
2
3
Z O N E
Z O N E
Z O N E
1
2
3
A LL
WH I T E
WH I T E
ZO N E
ZO N E
ZO N E
O N L Y
O F F
ZO N E

Publicité

Table des Matières
loading

Produits Connexes pour SLV COLOR CONTROL SYSTEM

Table des Matières