2. Product Description
Diesel or Kerosene indirect-fired mobile/portable space heater with close combustion chamber
3. Technical Specifications
Model
Heat Input* [kW] [Hs]
Air Flow Rating [m³/h]
Fuel Type
Fuel consumption [l/h]
Fuel Nozzle size [gph]
Voltage [V/Hz]
Air Pressure Setting [bar]
Current Rating [A]
Electricl power Rating [W]
Fuse Rating
Dimensions
Net Weight (kg)
Length (mm)
Width (mm)
Height (mm)
Tank Capacity (l)
Operating range (h)
Standard Accessories
Fuel gauge
Handle
Ambient thermostat
Malfunction detection signal
* Based on Gross Calorific Value [Hs]
* Based on dedicated setting for standard condition (atmospheric pressure 1020 hPa and Temperature 15 °C).
4. Assembling Instructions
Extract the heater from its carton. If the unit is anyhow damaged, do not use it and contact your dealer.
The following accessories are supplied in the shipping carton:
To assemble the heater, proceed as follows (see Fig. 1):
DH2-I-20C
17.5
650
Diesel - Kerosene
1.6
0.55
230/50
0.36
1.1
230
T3.15A
23.0
845
420
550
20
~13
yes
1
built-in
built-in
Fig.1
DH2-I-30C
30.7
1100
Diesel - Kerosene
2.8
0.85
230/50
0.36
1.8
370
T3.15A
35.0
1095
575
675
39
~14
yes
1
built-in
built-in
Pos.
Description
A
Handle
B
Flue connection
C
Screw M5
D
Heater body
E
Spring washer
F
Spacer
G
Wheel
H
Wheel shaft
I
Nut M5
J
Frame
Qty
1
1
8
1
2
2
2
1
8
1