The circulators must never be used for the circulation of domestic
water or in the foodstuffs field.
The circulators must never be used in refrigeration systems, air
conditioning systems and similar installations.
2.2 technical features
Model
Adjustment of the rotation speed
Power supply voltage
Max. motor power
Motor protection
IP Protection degree
Allowed temperature field*
Ambient temperature
Max. flow rate
Max. operating pressure
EEI
Adjustment of pressure difference
Minimum pressure on the intake opening**
Rated diameter DN (fitting)
Assembling center-to-center distance
Temperature range for storage
Conditions of max. relative humidity
* To avoid condensation in the motor and the electronics the temperature of the pumped
liquid must always be greater than the ambient temperature.
** To avoid cavitation noise, minimum pressure values on the intake opening must be
strictly respected.
*** The benchmark for most efficient circulators is EEI ≤ 0,20.
2.3 Description of the circulator
Wet rotor circulator with integrated frequency commutator (INVERTER).
No mechanical seal is required. No protection against overload is required. The
motor is protected against short-circuit operation.
The motor is integrated with an electronic module allowing the adjustment of the
head/pressure difference from 1.7 m to 5.7 m (with Q = 0 m
Adjustment elements located on the terminal board box:
- Trimmer to adjust the rotation speed value set at output.
- Warning light (LED) of commissioning / fault signaling.
energy Saving 15(25)[32] - 60 /130(180)
energy Saving Solar 15(25) - 60 /130(180)
Manual by trimmer
1X230 V -10%/+6%, 50 Hz
53 W
Not required
IP 44
+2°C to +95°C (Ref. Tab. 1)
+2°C to +110°C (Ref. Tab. 1)
0°C to +40°C
3 m
/h
3
0.6 MPa (6 bar) mod. energy Saving
1.0 MPa (10 bar) mod. energy Saving Solar
≤0,27 - Part 2 ***
1.7 m to 5.7 m
0.03 MPa (0.3 bar) at 50°C
0.10 MPa (1.0 bar) at 95°C
0.15 MPa (1.5 bar) at 110°C
15 (G 1) - 25 (G 1 1/2) - 32 (G 2)
130 mm - 180 mm
-20°C to +70°C
95% at +40°C
3
/h).