1. The wall temperature have to be similar to walls/floor of monitored area
2. The sensor have to be aimed away from windows and reflected sunlight
3. The sensor have to be aimed away from heaters or heater/cooler outlets
4. The sensor have to be aimed so that likely intruder paths cross three views
5. Please leave clear line-of-sight from sensor to monitored area
Note: glass will block PIR sensor 's view; metal will block microwave sensor's view
Warning: Do not partially or completely hinder the view of the detector
Wall Mounting
1. The sensor base have to be fastened flat on vertical wall (± 2 degrees)
2. The sensor have to be mounted at 2,3m or 3m height from the floor
Mounting Bracket
1. Bracket fastened to semi-vertical surface (± 15 degrees)
2. The sensor have to be fastened flat on bracket on vertical wall
If there is a way for intruders to pass only a very short distance in the sensor's view
or if aggressive detection is required then use HIGH sensitivity (JP2 OFF) otherwise
LOW sensitivity is fine for ordinary applications.
FUNCTION
PIR / MW LED
Number of Steps
Sensitivity
Alarm LED
*Using this setting you can remotely manage the switching on of the LEDs via the
clamp 'LED EN'. By applying a 12V voltage (system armed) the LEDs will signal an
alarm detection.
INSTALLATION INSTRUCTIONS
OPERATION PROGRAMMING JUMPERS
JP
ON
1
ENABLED
2
3 - 5
3
LOW
ENABLED
OFF
DISABLED*
1 - 3
HIGH
DISABLED
9