3 Safety Notes

The insertion module corresponds to all relevant
directives of the EU and is therefore marked
with
.
The module must be installed by skilled per-
sonnel only .
The module is suitable for indoor use only .
Protect it against dripping water and splash
water, high air humidity and heat (admissible
ambient temperature range: 0 – 40 °C) .
Immediately switch off the amplifier contain-
ing the module
1 . if the module or the amplifier is visibly
damaged,
2 . if a defect might have occurred after the
unit was dropped or suffered a similar ac-
cident,
3 . if malfunctions occur .
In any case the module (with the amplifier)
must be repaired by skilled personnel .
For cleaning only use a dry, soft cloth; never
use water or chemicals .
No guarantee claims for the module and no
liability for any resulting personal damage or
material damage will be accepted if the mod-
ule is used for other purposes than originally
intended, if it is not correctly installed or op-
erated, or if it is not repaired in an expert way .
If the module is to be put out of oper-
ation definitively, take it to a local recy-
cling plant for a disposal which is not
harmful to the environment .
4 Installing and
Connecting the Module
WARNING Always disconnect the mains
plug of the amplifier from the
socket before installing the
module: Risk of electric shock!
1) Unscrew the housing cover of the amplifier .
2) On the front panel of the amplifier, unscrew
the cover plate of the insertion compartment .
Remove the three-pole cable glued to the
cover plate . Insert the module and fasten it .
Then connect the cable to the pin connector
AN07 AUDIO (see page 2) . Thus, the module
is supplied with ⎓ 17 V and the audio signal
is sent to the amplifier .
3) To install the connection plate provided (a),
unscrew the corresponding cover plate on
the rear of the amplifier or detach the corre-
sponding cover plate . Insert the connection
plate into the opening and fasten it with
screws .
4) Connect the connection plate to the module
according to the figure on page 2 .
5) Before closing the housing cover of the am-
plifier, store an emergency message (chap-
ter 5 .1) . A message can only be stored or
deleted via the operating elements (b – f) on
the PCB . This will prevent inadvertent dele-
tion, for example .
6) For alarm triggering and thus for automatic
replay of the stored emergency message, con-
nect a corresponding alarm contact (normally
open contact) to the alarm input E / M of the
connection plate (a) .
7) The relay contacts FAULT MONITOR of the
connection plate allow to connect additional
units for alarm transmission . The power rat-
ing of the relay contacts is 1 A at ⎓ 24 V or
~ 120 V .
8) If a 24 V operating voltage is required, e . g .
for an additional alarm relay, this voltage
can be picked off at the terminals "24 V⎓"
of the connection plate . The power rating is
40 mA . However, this 24 V voltage will only
be applied during an alarm . (The alarm con-
tact connected to the terminals E / M must
be closed .)