6.2 Combustion air

The required oxygen for the fire is supplied through inlet below the door of the appliance.
An optimal combustion requires sufficient fresh air (see technical data). A lack of oxygen may result in
incomplete combustion and reversing flue gases.
ATTENTION!
Extractor fans when operating in the same room or space as the appliance may cause problems.
Additional combustion air can be supplied by placing an air inlet grill as close as possible to the appliance. Air
inlet grills must be positioned so that they are not liable to blockage.
Combustion air can also be supplied from the outside. To do so, a steel pipe must be connected to the
external air adaptor (optional). This is performed as follows:

Rear connection

Remove the pre-cut cover on the rear of the convection
1.
mantle.
Link the connector with the pipe for the combustion air
2.
using a tie down strap. Then secure the connection on the
rear of the combustion chamber with 3 screws.
Place the cover plate around the pipe and screw it tight.
3.
Bottom connection
Remove the pre-cut cover at the bottom of the mantle.
1.
Secure the connector on the rear of the combustion
2.
chamber using the 3 screws included
Place the connection in the connector and secure the
3.
connection on the convection mantle using the 2 remaining
screws.
The combustion air connection at the bottom requires a height
under the convection mantle of 120mm and a depth behind the
convection mantle of around 50mm.
48