English
How to set the "OFF" timer
This function enables you to set the length of time you want the airconditioner to operate.
You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments.
1. When airconditioner is operating, press the 'Off
Timer' button and set the length of time you want
by pressing ▼ or ▲. Each time you press the button
you will increase the 'time to off' period by 30mins. up
to 10 hours, and 1 hour thereafter up to 24 hours.
The display will show .5 for 30min and 1 for an hour.
e.g. One and a half hours will show 1.5.
3. If you press the 'Off Timer' button during its
operation, the remaining time will be shown.
+ 1 hour
'Error' and warning indicators
The machine's safety devices will automatically send signal for any problems via the display window on the
control panel. The information below shows how to read these signals.
1. WATER FULL
When the water container is full,
"FU" is displayed and the LED
"Water Full" light will be On.
4. LOW PRESSURE
'E2' is displayed and the 'Error'
LED will be On when the pressure
of the compressor is too low.
18
2. When you have finished setting the time period,
the 'Off Timer' lamp will be ON, which indicates the
airconditioner is in sleep (Off Timer) mode.
4. To CANCEL timer, press 'Off Timer' button l or
ONE second . lt will then switch the timer off
automatically.
2. ALIGN WATER TANK
If the water tank is not positioned
correctly, the LED "Align Drain
Tank" light will be On.
5. SENSOR PROBLEM
If the thermistor is short circuited
or cut, 'E3' is displayed and the
'Error' LED will be On.
56.001.599 - rev. 03 - 2020
"OFF TIMER" LED is on
1 sec.
3. HIGH PRESSURE
'E1 ' is displayed and the 'Error'
LED will be On when the pressure
of the compressor is too high and
the high pressure switch is open.
6. ANTI FREEZING
When the temperature of the
evaporator is below -2°C, 'AF' is
displayed and the 'Error' LED will
be On.
THERMOBILE
Coolmobile 21-25