Philips GP LED production module 150 Guide D'installation Rapide page 2

Publicité

IMPORTANT!
WARNING
Turn off and disconnect the power before installation. Installation must
be performed by a qualified electrician in accordance with all national and
local electrical and construction codes and regulations.
• Make sure that power cords are routed in a manner that will prevent
incidental damage
• Use wet-rated (IP66) junction boxes which are also suitable for the
power cords used in the application.
• Use a strain-relief or power cord grip if needed.
• Use a cord grip suitable for use with three conductor and type
of cord suitable for the trade size of the junction box provided by
others, if needed.
• DO NOT connect to live power until installation is complete.
• DO NOT attempt to install or use until you have read and
understood the installation instructions contained in this Quick
Installation Guide, the Application Guide and safety labels.
• DO NOT modify or alter the product; doing so will void the warranty.
NOTE
The light source of this fixture is not replaceable. When the light source
reaches its end-of-life, the whole fixture needs to be replaced.
PHOTOBIOLOGICAL HAZARD
Photobiological safety of lamps and lamp systems (EN 62471).
This International Standard describes the photobiological safety of lamps
and lamp systems including luminaires.
The rating of the GreenPower LED production module according
to this standard can be found in the table below.
In case of Risk Group 2: Do not stare at the operating light source.
The philosophical basis for this classification is that the lamp
does not pose a hazard due to the aversion response to very
bright light sources or due to the thermal discomfort.
CLEANING AGENTS, CROP PROTECTORS AND OTHER CHEMICALS
For advice on chemicals that may be used in combination with the
modules (for cleaning, fungicides, surfactants, etc.) please see the
Application Guide.
Photobiological hazard /
Risques photobiologique
GP LED production 2.2 DR/B LB HO
GP LED production 2.2 DR/B/FR LB HO
GP LED production 2.2 DR/W LB HO
GP LED production 2.2 DR/W/FR LB HO
Dimensions
Product name / Nom du produit
GP LED production module 150
W1
Accessory information / Information sur les accessoires
There is a comprehensive range of accessories available for the installation and connection of this product. More information about these accessories can be found in the Application Guide.
Une gamme très complète d'accessoires est disponible pour l'installation et la connexion de ce produit. Vous trouverez de plus amples informations sur ces accessoires dans le Guide d'Application.
Mounting bracket /
Clip de montage
Make sure the connection to the power is made in such a way it is suitable for wet conditions (e.g. use a wet-rated (IP66) junction box) / Assurez-vous que la
connexion à l'alimentation est réalisée de façon à convenir à des environnements humides (utilisez p.ex. une boîte de jonction homologuée IP66).
This module operates on the AC range mains 120-277 V. For more detailed information please check the Application Guide, which is available via a Philips contact
person / Ce module fonctionne avec une tension d'alimentation AC de 120-277V. Pour des informations détaillées veuillez consulter le Guide d'Application
disponible auprès de votre intermédiaire Philips.
© Philips Lighting Holding B.V. 2018. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at
any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
© Philips Lighting Holding B.V. 2018. Tous droits réservés. Philips se réserve le droit d'apporter des changements aux spécifications et/ou
d'interrompre un produit à tout moment sans préavis ni obligation et ne sera pas tenu pour responsable de toute conséquence résultant de
l'utilisation de cette publication.
Document order number / Numéro de commande du document: 4422 945 57941 A
01/2018
Data subject to change / Données sujettes à modification
EN
Radiation hazard - Retinal Blue /
Minimum viewing distance
Risque du rayonnement - bleu
(meter/inch) / distance
rétinien
d'observation minimale
(mètre/pouces)
Risk Group 2 / Group de Risque 2
0.3/12
Risk Group 2 / Group de Risque 2
0.3/12
Risk Group 2 / Group de Risque 2
0.8/29
Risk Group 2 / Group de Risque 2
0.8/29
Product dimensions (mm/inch) / Dimensions du produit (mm/pouces)
L1
L2
L3
1513/59.567
700/27.5
64/2.52
L1
Power / data cables /
Câble d'alimentation
IMPORTANT!
AVERTISSEMENT
Coupez et déconnectez l'alimentation avant de procéder à l'installation. L'installation doit être
effectuée par un électricien qualifié conformément à tous les codes et réglementations d'électricité et
de construction nationaux et locaux.
• Assurez-vous que les cordons d'alimentation sont acheminés de façon à éviter tout dommage
accessoire.
• Utilisez des boîtes de jonction homologuées pour emplacements mouillés (IP66) qui conviennent
aux cordons employés dans l'application.
• Si nécessaire ayez recours à un soulagement de traction ou à une traction de cordon
d'alimentation.
• Utilisez un presse-étoupe adapté pour être utilisé avec un câble 3 conducteurs et qui correspond
avec le type de boîte de jonction.
• NE connectez PAS à une source d'alimentation active tant que l'installation n'est pas terminée.
• NE tentez PAS d'installer ou d'utiliser le module avant d'avoir lu et compris les instructions
d'installation figurant dans le présent Guide d'Installation Rapide, le Guide d'Application et les
étiquettes de sécurité.
• NE modifiez PAS ou N'altérez PAS le produit sans quoi la garantie serait annulée.
REMARQUE
La source lumineuse de cet appareil d'éclairage n'est pas remplaçable. Lorsqu'elle arrive en fin de
vie, tout l'appareil doit être remplacé.
RISQUES PHOTOBIOLOGIQUE
Sécurité photobiologique des lampes et des systèmes d'éclairage (EN 62471).
Cette norme internationale définit la sécurité photobiologique des lampes et des systèmes d'éclairage,
y compris les luminaires.
Le classement selon cette norme du GreenPower LED production module se trouve dans le tableau
cidessous.
En cas de Groupe de Risque 2: ne pas regarder directement dans la source de lumière.
La base de raisonnement pour la classification est que la lampe ne présente pas un
risque lié à la réponse d'aversion pour les sources à lumière très brillante ou en raison
de l'inconfort thermique.
PRODUITS DE NETTOYAGE, PRODUITS PHYTOSANITAIRES ET AUTRES PRODUITS CHIMIQUES
Pour des conseils au sujet des produits chimiques susceptibles d'être utilisés conjointement avec les
modules (produits de nettoyage, fongicides, agents de surface, etc.), veuillez vous reporter au Guide
d'Application.
All other radiation hazards /
Tous les autres risques de
rayonnement
Exempt group / Group sans Risque
Exempt group / Group sans Risque
Exempt group / Group sans Risque
Exempt group / Group sans Risque
EU
D1 Ø
D2 Ø
19/0.748
8.7/0.343
L2
D2 (Ø)
D1 (Ø)
L3
Connectors and end caps /
Connecteur (incl. obturateur)
NAM
D2 Ø
W1
H1
7.6/0.299
40.5/1.594
40.2/1.583
10 / 0.39
32 / 1.26
Cable trees /
Faisceau de câbles
www.philips.com/horti
e-mail: horti.info@philips.com
FR
Product weight /
Poids du produit
(kg/lbs)
1.7/3.7
40 / 1.57