6.3 GENERAL PERFORMANCE
Power requirement
Dimensions (W x H x D)
Weight
6.4 ENVIRONMENTAL CONDITIONS
• Temperature
• Humidity
• Max. wet bulb temp.
6.5 PICK UP LASER
• Type
• Wave Length
• Divergence
• Output power
CHAPTER 7 BEFORE REQUESTING SERVICE
7.1 TROUBLESHOOTING
(1) There are many kinds of problems caused by misuses. When a problem occurs,
check the table below which describes possible problems occurring with your
SuperDisk drive.
(2) If the SuperDisk drive does not operate correctly and you cannot restore operation
by the following detailed procedures in the table, do not remove the cover of the
units or adjust further.
(3) In the case of (2) above, unplug the unit and consult with your dealer or the nearest
service station.
TROUBLE
• SuperDisk drive does not
operate and Busy Indicator
does not light.
+5 V
101.6 x 25.4 x 150 mm (exclude Front Bezel)
475 g typ.
Operating
5 ~ 45 °C
20 ~ 80 %Rh
29 °C
(Non-condensation)
Semiconductor laser GaAlAs
795 ± 20 nm
θ
= 30° ~ 36°
v
3.6 mW
CORRECTION
Ensure that the connection between the SuperDisk
drive and the host computer is correct.
Ensure that the Device Driver installation has been
completed.
Ensure that the setting drive select switch is correct.
Ensure that the disk has been inserted label side up and
shutter side head.
Ensure that foreign objects are not inserted.
2.7 A max
Non-operating
–30 ~ 60 °C
5 ~ 90 %Rh
29 °C
(Non-condensation)
A-7