SMS commands
The device has a set of configuration and control commands that can be sent via SMS. The command mes-
sage is always protected by a password.
The format of the command message is as follows:
[PASSWORD]#[COMMAND] for example:
Where the password is always 4 characters and # (hashtag) is a mandatory separator.
Activation commands
The -NR command disables the feedback response (case sensitive)
The temperature sensor is deactivated by default.
Command
Description
0 [-NR]
Disables the relay output
1 [-NR]
Activates the relay output
?
Status request
A[1-69] [-NR]
Activates temperature-dependent relay
output (thermostat function)
M[1-240] [-NR]
Activates the relay output for a period be-
tween 1 and 240 minutes
Configuration commands
These commands allow you to activate/deactivate functions via SMS.
Command
Description
T[0-1]
Enable/disable the temperature sensor
V[0-1]
Enable/disable the supply voltage
W[0-1]
Enable/disable the manual button
P[0000-9999]
Change password
Phone call function controls (RING)
Command
Description
RM[0-2]
Enable/disable the RING mode
RM0=OFF, RM1=Switch,
RM2=Pulse
RR[0-1]
Enable/disable the feedback SMS
response
RF[0-1]
Enable/disable the list of author-
ized users
RA:[NUM];[NAME]# Add a user to the list
RD:[NUM/NAME]#
Delete a user from the list
RB
Performs the function of tele-
phone call, but with an SMS
0000#1 (relay switching on)
Example
0000#0
0000#1
0000#?
0000#A21
0000#A8
0000#M5
Example
0000#T1
0000#V1
0000#W0
0000#P1234
Example
0000#RM0
0000#RM1
0000#RM2
0000#RR1
0000#RF1
0000#RA:+41798527511;
Rossi M.#
0000#RD:+41798527511# User deleted!
0000#RB
Response
RE1:OFF
RE1:ON
RE1: ON Ta: +16.9C Th:+21.0C
RE1: OFF Ta: +16.9C Th:+8.0C
PULSE EXECUTED: 5min
Response
Ta: +16.9C
Vi: 12.3V
BUTTON:DISABLED!
NEW PASSWORD: 1234
Response
RMODE: OFF
RMODE: SWITCH
RMODE: PULSE
RING SMS REPLY ENABLED!
RMODE: PULSE FREE
User added:
+41797654321
Free space: 599/600
Free space: 600/600
13