It is advisable to do the installation so that each cycle starts in the shallow area and ends in the deep area.
Wait for 24 hr. after adhering before performing the pressure test on the whole installation.
The recommended operation time of the valve to keep the swimming pool clean will be the same as the time used by
the filtering system. Therefore the electrical supply of the equipment should be controlled with the same timer as
the filtering system.
4. START-UP
Programming the electronic panel:
The panel is programmed by four pushbuttons, which have the following function:
P
To enter the programming menu and memorise the changes made.
Move the cursor to the position you wish to modify.
and
Increase or decrease the value of the position where the cursor is placed.
Method:
1. To enter the programming menu simply press key "P". The cursor will be displayed under the valve number
and the programmed time for this valve will be given.
2. By using pushbuttons
3. Press key
to place the cursor on the digit you wish to vary, and by using the pushbuttons • and
the required value (a separate time can be selected for each electrovalve between 0 and 240 sec. in steps
of 5 seconds. The times of the 12 possible electrovalves must be programmed bearing in mind that the
ones that are not used must be set at 0 sec.)
4. Press key "P" to store the changes made (an M appears on the right of the Display screen to confirm that
changes have been stored). Whenever a value is modified, it must be stored before 20 sec. otherwise the
apparatus leaves the programming mode automatically and if data are not stored, the modifications made
will be lost.
5. OPERATION
During normal operation, the Screen displays the number of the electrovalve activated and the time left to change to
the following one.
The changeover overlaps with the two valves activated for one second. If you do not wish to activate a valve, simply
set the time to zero.
Required phases to start-up the system:
1.- Cleaning the circuits:
Dismantle the electrovalves.
Fill the swimming pool above the suction inlet of the system.
Switch on the pump. If the filter is connected to the outlet of the pump, place the filter valve in the recirculation
position.
2.- Pressure test:
Place the winter caps in each nozzle.
Place the system under a pressure of 2.5 Kg/cm².
Empty the pool once the test has been performed and the caps removed.
3.- Start-up:
Place the inner unit in each of the nozzles.
Fill the pool.
If the filter is connected to the pump outlet, place the filter valve in the filtering position.
Finally, switch on the pump.
Before filling the pool, start-up the ELECTRONIC NET'N'CLEAN SYSTEM, and the protection caps of the nozzles
will be forced out by the water pressure. Once the protection caps have been removed, place the inner unit by
turning left to "CLOSE" . It is now ready for use.
and
locate the valve of which you wish to modify the action time.
4
enter