Vimar SL24.T Guide Rapide page 8

Masquer les pouces Voir aussi pour SL24.T:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
SL24.T
OFF
ENCB
ON
OFF
31
ON
OFF
32
ON
OFF
51
ON
OFF
52
ON
OFF
61
ON
OFF
62
ON
OFF
63
ON
Gate travel calibration
NOTE: To perform this procedure, the gate must be stationary.
CAUTION! THE SAFETY DEVICES ARE DISABLED DURING GATE TRAVEL CALIBRATION.
Before performing calibration, check the direction of the motor (DIP 10 = OFF, opening to the left, DIP 10 = ON opening to the right).
OPENING
APERTURA
Quick calibration
(slow-down at 50 cm during opening and 75 cm during closing, pedestrian opening at 1 metre)
Press
No.
Step
push-button
1
-
Preparation
2
PROG
Procedure activation
3
51
Gate closing
4
-
Gate opening
5
-
Gate closing
6
-
End of procedure
6
When the motor is operating: second encoder channel signal absent (encoder not working)
When the motor is operating: second encoder channel present (it flashes very fast, depending on the motor rotation
speed)
Limit switch 1 contact (RH magnet-holder bracket) open (limit switch engaged)
Limit switch 1 contact (RH magnet-holder bracket) closed (limit switch engaged)
Limit switch 2 contact (LH magnet-holder bracket) open (limit switch engaged)
Limit switch 2 contact (LH magnet-holder bracket) closed (limit switch not engaged)
Step-by-step input (term. 51) not engaged
Step-by-step input (term. 51) engaged
Pedestrian input (term. 52) not engaged
Pedestrian input (term. 52) engaged
Stop contact (term. 61) open (engaged)
Stop contact (term. 61) closed (not engaged)
Closing photocell (term. 62) engaged
Closing photocell (term. 62) not engaged
Photocell or safety edge (term. 63) open (engaged)
Photocell or safety edge (term. 63) closed (not engaged)
OPENING
APERTURA
Description
Move the gate to approximately 1 metre from closing
Press the programming pushbutton PROG for at least 3 seconds, until the PRG LED starts flashing
slowly, and then release it
Press pushbutton 51: the motor closes at reduced speed up to the closing limit switch
The motor opens at reduced speed up to the opening limit switch
The motor closes at normal speed up to the closing limit switch
The PRG LED turns off. End of procedure
ON
1
2
3
4
ON
1
2
3
4
EN
5
6
7
8
9 10
DIP1
5
6
7
8
9 10
DIP1

Publicité

Table des Matières
loading

Table des Matières