SPECTRE Module Industry - SMI
Frequency Band: 865 - 868 MHz
Frequency Band: 902 - 928 MHz
To supply model or to provide V+, V- use only power adaptors with outputs in compliance with ES1 and PS2 (LPS per Annex Q of IEC/UL/EN 62368-
1) types.
V+, V- musn't exceed 30 VDC
Main power supply:
Range +12 Vdc up to +30 Vdc
Consumption:
Typical: 0.6 A under +24 Vdc
SMI/SLI-POE+:
Use an IEEE 802.3at.2009-compatible PSE (Power Sourcing Equipment)
Main power supply:
Range +42.5 Vdc to +57 Vdc
If several readers are connected to the PSE, check that each port of the PSE supplies 20W
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) (SUB D9) / Ethernet (RJ45) / USB C (wedge mode)
Temperature:
-25 to +60 °C / -13 to +140 °F
Protection:
IP53 level
Chip:
EPC1 Gen2 (ISO 18000-63) - 1 to 62 bytes max
I/O:
4 optocoupled inputs and 4 optocoupled outputs
Module LED:
1 red LED: presence of power supply
Antenna LED:
7 colors (red, green, blue, orange, purple, turquoise, white) controlled by SSCP commands.
Use a multi-conductor shielded twisted pair cable.
Max length RS485:
3 280 ft / 1000 m at 9600 baud (SYT2 AWG24 recommended).
Max length RS232:
49.21 ft / 15 m (SYT2 AWG24 recommended).
Ethernet:
100m, category 5E.
Install the module/reader away from computer transmission cables or from power sources (ex: RJ45, sector...).
The disruptions that they can cause can vary according to their radiation power and their proximity.
Use a filtered and regulated power supply.
Antennas connected to different modules/readers may interfere with each other. Move them away from each other.
A power supply which provides 1 A min under +24Vdc is recommended.If the IN/OUT are powered by the module, use a 2A min under +24Vdc power supply.
Users must not remain within a range of less than, 34 cm / 13.39 in from an antenna for an extended period of time as per EN50364 applicable to this
type of device.
Apart from the hatch the module housings must not be opened.
Before any service operation you must de-energize reader.
Check that the hatch seal is correctly positioned before closing.
Power jack
Power plug S761K
SPECTRE UHF
Installation procedure
SMI-W42-A-U04: RS232
SMI-W43-A-U04: RS485
SMI-W44-A-U04: TCP-IP + POE
SMI-W52-A-U04: RS232
SMI-W53-A-U04: RS485
SMI-W54-A-U04: TCP-IP
Power Supply Characteristics - SMI /SLI
Typical: +24 Vdc
Max: 0.8 A under +24 Vdc
Typical: +48 Vdc
Recommended Cables - SMI / SLI
Front View of the Module - SMI / SLI
RJ45
DE9
M12
RS232/ RS485 / IN/OUT CONNECTION - SMI / SLI
DE9:RS232
Tx
Rx
GND
Configuration of the interface board SMI / SLI
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1128X01 - Page 1 sur 12 - Ed. 08/01/2020
UHF SPECTRE
Notice d'installation
Frequency Band: 865 - 868 MHz
ERP: 2W
Frequency Band: 902 - 928 MHz
EIRP: 4W
Characteristics - SMI / SLI
Recommendations - SMI / SLI
Red LED
USB C
RF port 2
RF port 1
DE9:RS485
GND
L- / B
L+ / A
UHF SPECTRE
Manual de instalación
SPECTRE Reader Industry - SLI
SLI-W42-A-U04: RS232
SLI-W43-A-U04: RS485
SLI-W44-A-U04: TCP-IP + POE+
SLI-W52-A-U04: RS232
SLI-W53-A-U04: RS485
SLI-W54-A-U04: TCP-IP + POE+
RF port 3
RF port 4
1
M12 A-coded: IN/OUT
2
3
4
5
6
7
8
9
10
11
12
US
FR
ES
+Vcc
OUT1
IN3
V- OPTO
IN1
GND
V+ OPTO
OUT4
OUT3
OUT2
IN2
IN4