DUROFIX RI20126 Manuel Informations Du Produit page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Always follow the procedure below to install a socket.
1. Insert a socket into the anvil (1).
2. Make sure the socket is fixed in the anvil while clicking on the ball of the anvil.
REMOVING SOCKETS
Always follow the procedure below to remove a socket.
CAUTION
FUNCTIONS & DISPLAY:
1. When pressing VSR switch, then the illuminative LED will be on at the same time.
2. There are 50 stages of torque clutches (within the 25-170Nm) and one "MAX"
stage in 250Nm in forward rotation.
3. Release the trigger
4. Press the torque range button to set the stage.
5. Then use the following torque meter to check the torque.
6. If the torque is not your target torque. Repeat the step 3 and step 4, until the torque
reach your target torque.
REFERENCE LABORY TORQUE VALUES OF EACH TORQUE CLUTCH
STAGE
Stage 00: Max. Torque value: 250 Nm (185 ft-lbs)
Stage 01: average value: 25 Nm (18.5 ft-lbs)
Stage 05: average value: 37 Nm (27.5 ft-lbs)
Stage 10: average value: 52 Nm (38.5 ft-lbs)
Stage 15: average value: 67 Nm (49.5 ft-lbs)
Stage 20: average value: 82 Nm (60.5 ft-lbs)
Stage 25: average value: 97 Nm (72.0 ft-lbs)
1English1
Always set switch (5) to off position when installing and
removing socket.
OPERATION
Fig. 3
English
-10-

Publicité

Table des Matières
loading