Important notes

• Installation, commissioning and maintenance must be performed only by a
qualified expert in accordance with the instructions provided, legal requirements
and recognised engineering standards.
• All technical connection regulations specified by the local water and electricity
supply companies must be observed.
• The power supply should be switched off before any work is carried out.
• The battery compartment with battery or plug-in power supply must be ordered
separately (see
• We reserve the right to make changes.
5.

Application

Hygiene unit for F5L-Mix single-lever mixer for automatic hygiene flushing and
program-controlled thermal disinfection.
Inside housing for wall mounting with battery or mains power.
Integrated control function:
– Hygiene flush (3 minutes), fixed interval – every 24 hours
Adjustable functional parameters via optional bidirectional remote control:
– Fixed interval (1-255 hours) and flushing time (1-255 seconds) for automatic
cold and hot-water hygiene flush
– Activation of thermal disinfection (application time 5 minutes, cooling time 1 minute)
– Setting of application time (1–255 minutes) and cooling time (1–255 minutes)
for thermal disinfection
6.

Technical specifications

Operating voltage:
Power consumption:
Protection class:
Bypass volumetric flow at a flow pressure of 3 bar:
Hygiene flush:
Thermal disinfection:
7.

Scope of delivery

8.

Dimensions

Chapter
19.).
6-24 V DC
3 W
IP 67
0.03 l/s
0.05 l/s
0.02 l/s