7.
Assembly Instructions
Fastening the
7.1
A: Actuator 1 (violet)
B: Actuator 2 (yellow)
C:Analogue output 0-10 V
D:Temperature sensor, cold water
E: Temperature sensor, hot water
F: Sensor connection 1
F: Sensor connection 2/3
H:Electrical T-junction, system lines (Power)
K: Electronic module
☞
To obtain an improved heat flow, it is recommended to place a few drops of heat
transfer compound (to be provided by the customer) on the
surface sensor
Place the
7.2
Place the soft-binder (c) around the
7.3
Connect the red surface sensor to the temperature sensor input 1 (E) of the elect-
7.4
ronic module (K); if necessary use the extension cable.
Optional: Connect the blue
7.5
electronic module (K); if necessary use the extension cable.
Squeeze the wire-end ferrules (e) onto the actuator lines (d).
7.6
Connect the actuator lines to the actuators (e. g. solenoid valve).
7.7
Caution!
Pin assignment table must be observed.
Connect the actuator lines (d) to the actuator distributors (L).
7.8
Electroni
cmodule
violet
yellow
Connect the actuator distributor to the actuators (A, B) of the electronic module (K).
7.9
7.10 Connect the electronic module (K) to the power supply.
A3000 open electronic module circulation heater
(b) on the pipeline (a).
surface sensor
Distri-
Actuator
butor
violet
1_1
yellow
1_2
violet
2_1
yellow
2_2
surface sensor
and the pipeline, and hook it in.
(b) to the temperature sensor (D) of the
.
surface sensor
(b).
5