CODE
POSSIBLE CAUSE
17
Detergent type oil being used in pump
18
Extension cord is wrong length or gauge
19
Loose electrical connections
20
Possible defective motor or starting capacitor
21
Paint spray on internal motor parts
22
Fuse blown, circuit breaker tripped
23
Tank pressure exceeds pressure switch cut-in pressure
24
Pressure release valve on pressure switch has not
unloaded head pressure
POSSIBLE SOLUTION
Drain oil and refill pump with D
oil.
Check for proper gauge wire and cord length. See
Extension Cords under Installation.
Contact a D
WALT factory service center or a D
E
authorized service center.
Contact a D
WALT factory service center or a D
E
authorized service center.
Contact a D
WALT factory service center or a D
E
authorized service center. Do not operate the compressor in
the paint spray area. See flammable vapor warning.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact a D
a D
WALT authorized service center.
E
19
WALT synthetic compressor
E
WALT
E
WALT
E
WALT
E
WALT factory service center or
E