Charging Phases; Trickle Charge; Technical Data; Maintenance And Repair - AKO 371017/011 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6

5. Charging Phases

5.1 Diagnosis & Recovery
As soon as a charging instruction has been transmitted to the charger, the unique function automatically checks the status of the battery
(detects voltage). If a drained battery has a voltage of over 4.5 V ± 0.5 V (for 12 V batteries) or 16 V ± 0.25 V (for 24 V batteries), the charger
starts to recharge the battery's original voltage with 1.5 A.
CAUTION! Do not charge 6 V batteries.
5.2 Main charging phase
80 % of the energy is returned in this phase. The charger operates here in several stages:
• For 24 V batteries: Either select 2 A for slow charging or 5 A for medium charging, depending on the type of use.
• For 12 V batteries: Either select 2 A for slow charging, 5 A for medium charging and 10 A for fast charging, depending on the type of use.
5.3 Absorption capacity
If you use a constantly high current for a longer period of time, you risk outgassing the battery. You should therefore use lower energy
(e. g. 1.5 A) to increase the voltage, e.g. from 28.2 V to 28.8 V (for 24 V batteries) or 14.1 V to 14.4 V (for 12 V batteries).
A full charge is almost 100 % guaranteed in this phase.

5.4 Trickle charge

The charger continuously monitors the voltage at the terminals to determine whether a trickle charge needs to be started. If the voltage drops
below 25.6 V (with 24 V batteries) or 12.8 V (with 12 V batteries), the unit starts charging the battery with charging pulses of a constant 1.5 A.
Trickle charging is constantly repeated to ensure that the battery is always kept in good condition. If the battery is not in use, it should always
remain connected to the battery charger.
5.5 13.6 V supply
5.5.1 Maintenance of 12 V lead-acid batteries: This mode is ideal for maintaining 12 V batteries with a capacity of 14 - 230 Ah.
The charger delivers a constant output of 13.6 V / 5 A. This is the maintenance mode for applications where maximum battery capacity
is needed, such as Golf buggy batteries, street sweepers etc.
5.5.2 Energy source: It is also used as an energy supply unit without attaching a battery in this mode. The charger delivers 13.6 V / 5 A.
Here are the steps for selecting 13.6 V mode:
a. Disconnect the battery
b. Plug in the power cable
c. Press the MODE key for 3 - 5 seconds to enable the function

6. Technical Data

Input voltage (Input joules):
Output voltage (Output joules):
Efficiency:
Charging voltage:
Charging current:
Ambient temperature:
Types of battery:
Sound level:

7. Maintenance and repair

The device does not require maintenance, but should be thoroughly cleaned at regular intervals. In the event of a fault, the device must be
taken out of use immediately. Repairs must only be carried out following prior consultation with the manufacturer and be carried out by
a qualified electrician. Only use original spare parts.
Declaration of conformity
Albert KERBL GmbH hereby declares that the product / device described in these instructions complies with the fundamental requirements and other relevant stipulations
and regulations. The CE mark confirms compliance with the Directives of the European Union. The declaration of conformity can be viewed by visiting http://www.kerbl.de.
Electronic scrap
Disposing of this device after its service life is the responsibility of the operator. Please consult the valid national regulations. The device must not be disposed of in
household waste. In accordance with the stipulations of the EU Directive on the Disposal of Electrical and Electronic Devices, the device can be disposed of free of
charge at the local waste collection or recycling centre. Alternatively, it can be returned to retailers who offer a collection service. The proper disposal helps to ensure
environmental protection and prevents any adverse effects on human health and the environment.
105 - 125 VAC, 60 Hz or 200 - 260 VAC, 50 Hz
12 V and 24 V (auto-select)
> 75 %
14.4 V ± 0.25 V or 28.8 V ± 2%
10 A ± 10 % or 7.5 ± 10 % or 5 A ± 10 % or 4 A ± 10 % or
3 A ± 10 % or 2 A ± 0.3 A or 1.5 A ± 0.3 A
-10 °C to + 40 °C , Reduced output power
at higher temperature
12 V and 24 V lead-acid batteries (WET, MF, AGM and GEL)
< 50 db (Tested at a distance of 19.5 inches or 50 cm) with integral mini-fans

Publicité

Table des Matières
loading

Table des Matières