3. Performance Features
• Manufactured to the current state of the art, the 5-stage battery charger enables batteries to be charged
to almost 100 % of their original capacity.
• Automatic diagnosis, recovery, charging and maintenance of batteries for months - fully automatic charging/ maintenance.
• There are 5 output voltages available - 28.8 V, 29.4 V, 14.4 V, 14.7 V and 13.6 V
• The unit has a 9-stage charging strategy, i.e. 1.5 A - 10 A - 7.5 A - 5 A - 4 A - 3 A - 2 A - 1.5 A maintenance/retention and
13.6 V / 5 A power supply (constant voltage mains adapter)
• Equipped with two removable and replaceable colour-coded leads. One connecting lead with terminal crocodile clips and
one with eyelets for permanent connection.
• No danger of overcharging
• Electronically safe from operator error
• Non-sparking
• Overheating protection with integral mini-fans
• Protected against short-circuiting and incorrect wiring
• Works as a power generator (13.6 V / 5 A)
4. Operating Instructions
4.1 Connecting the terminal eyelets directly to the respective connectors on the battery.
NOTE! Make sure that the poles are connected up properly (correct polarity) before plugging in the unit.
4.1.1 Place the red terminal on the plus pole connector
4.1.2 Place the black terminal on the minus pole connector.
4.2. Plug the power cable into the wall socket.
4.2.1 Once connected, the Power LED will light up.
4.2.2 The charger automatically selects the correct voltage depending on the kind of battery and the corresponding LED display lights up.
Settings
14.4 V
Symbol
• Press the MODE key for 2 - 3 seconds to charge AGM batteries at temperatures below zero.
• The Error LED display lights up if the polarity is wrong
- Incorrect polarity
ON
- Bad batteries cannot be recharged
Flashes for 12 V batteries
Flashes for 24 V batteries
• Select the charging stage:
• For charging 12 V batteries: The standard 2 A charging stage can be changed by pressing the Mode key to 5 A or 10 A.
• For charging 24 V batteries: The standard 2 A charging stage can be changed by pressing the Mode key to 5 A.
• The charging status LED display indicates the battery charge at a percentage of 25 %, 50 %, 75 % and 100 %.
4.3. Disconnect the power cable from the wall socket when the unit is fully charged. Then disconnect the cable from the battery.
NOTE! Always disconnect the power cable from the socket before connecting the battery charger to the battery
or disconnect it from the battery.
14.7 V
28.8 V
29.4 V