ASSEMBLING THE DOSATRON (cont...)
2 practical scenarios that may be encountered:
1. The direction of the water flow in the Dosatron unit is identical to that
of your water supply system:
The unit can be directly installed without any preliminary work (please refer to
"Warning! Remove the battery protective tab on the EC reader")
2. The water flows in the opposite direction:
Open the casing fitted with
toggle latche
Unscrew the mixing unit
1
Unscrew the Dosatron regulator
2
©
DOSATRON INTERNATIONAL S.A.S / 19
Remove the EC reader
Unclip the dosing unit from bracket
1
Release the casing components
2
Unscrew the casing bracket and then screw
it at the other end of the casing. Turn the
EC reader shield the other way round
Fit the EC reader onto the casing
Fit the Dosatron regulator
Remove the battery protective tab
Fit the mixing unit onto the casing
©
DOSATRON INTERNATIONAL S.A.S / 20
Tightening torque: 1 Nm, i.e. 0.1 kg
ITurn components
the other way round and fit
1
them on the new face of casing
. The original rear
2
face of the casing is now facing forward and vice versa
Close back the casing
Install the Dosatron unit, as shown