Dolmar WD-2035 Instructions D'emploi page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
UK
2 .....
USE OF THE FILTER CARTRIDGE pack code
(fig. "B3" - "B4")
- Release the motor unit from the container-drum (fig. "A1") .
- Place the filter element (b) on the motor support (c) (fig. "B3").
- Fit the plastic adapter disc (a) on to the filter element (b) and clamp the two parts together by
turning the knob in a clockwise direction (fig. "B4").
- Fit the motor unit back on to the container-drum and clip it in place.
- Use of the filter cartridge is particularly recommended to clean up dust or solids. It can be used
together with the paper bag which, besides preventing the filter cartridge from clogging, also
transfers the vacuumed dirt in a rapid and hygienic way.
Do not use to vacuum sharp or wet materials.
3 .....
USE OF THE SPONGE FILTER code
- To clean up liquid substances, release the motor unit from the container-drum (fig. "A1").
- Attach the foam filter to the motor support as indicated in figure "B5".
- Place the motor unit back into the drum, making sure that the hinges fit into their slot.
4 .....
USING THE P.P. CANISTER-TYPE PRE-FILTER code
(fig. "B6")
The canister-type pre-filter must only be used with the cartridge filter element.
- Is particularly suitable when fine dust such as cement, talcum and so forth, must be filtered.
- Attach the canister-type pre-filter to the container-drum as indicated in figure "B6".
5 .....
OUTLET AIR POST-FILTERS code
- These electrostatic post-filters ensure that the air blown back into the room is free from
impurities.
-------------------------------------------------------------------------
C - USE OF THE APPLIANCE
1
....
FOR VACUUMING DUST AND DIRT
- Filter cartridge must always be fitted
ATTENTION:
2
....
USE AS A WET CLEANER
- Always remove the filter cartridge.
- Mount the sponge filter as indicated in point "B3".
ATTENTION:
- If this happens, immediately turn off the appliance and empty the container-drum.
• For good performance of the appliance, both bags must always be kept clean.
It is recommended to replace the cartridge after around 100 hours of use.
• When the vacuumed liquids reach the maximum tolerated level in the drum,
the suction action is automatically blocked by the safety float.
The user will be warned by the increase in the rpm rate of the motor.
668 083 201
668 083 035 (fig. "B5")
668 083 021 (fig. "B7")
- 14 -
668 083 100