Deltec MCE 300 Mode D'emploi Et Pièces Détachées page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Use with ozone
skimmers are suitable for use with ozone and will automatically suck the gas through the venturi
hose. A maximum volume of 25 mg/h should be used on tank volumes that are suitable for this skimmer. Do
not use excessive ozone, as it is dangerous and can cause severe headaches.
Maintenance
The Deltec skimmer range should need very little adjustment and maintenance once set correctly however
due to the high levels of calcium in marine aquariums it is common for deposits to build up on moving parts
requiring periodical cleaning. It is recommended every 3 months, or when required, that the pump is removed
from the skimmer.
Check and clean the impellor of debris. Make sure that the impeller rotates freely on the shaft. If not
submerge in lime scale remover.
A build up of calcium, dust and salt can restrict or block the air inlet (15) and reduce the skimming efficiency.
This should be checked and carefully cleaned with a toothpick or fine drill rotated between the fingertips. It is
advisable to stop the pump for approximately 15 minutes once every week in order to dissolve any dust or
salt crystals that may have collected in the air inlet.
Fault finding
Malfunction
Pump produces insufficient air
excessive air bubbles in
aquarium water
Pump is noisy
technical
Dimensions
data
(l/w/h) app.
MCE 300
260x175x445mm
MCE 300 UK 260x175x445mm
MCE 300 US 260x175x445mm
Cause
tap, airline or venturi blocked
airline kinked
ozonizer blocked
Air in suction line
caused by additives in certain
sea salts and water conditions
air tap closed to far
shaft (6) is blocked in rotor (7)
Power
air flow up
consumption
to app.
9,5 Watt
120 litre
9,5 Watt
120 litre
12 Watt
150 litre
Rremedy
clean
remove kink
clean
bleed
use different salt or feed heavily for a
period, empty skimmer cup frequently,
open air tap fully. This condition may
last for several weeks.
open air tap
clean in lime scale remover; free the
shaft by tapping it lightly on is end.
Replace bearing
min. water
aquarium
level for sump
size normal
240 mm
250 litre
240 mm
55 gallons
240 mm
66 gallons
EN
aquarium
size light
320 litre
70 gallons
84 gallons

Publicité

Table des Matières
loading

Table des Matières