LED Panel
These instructions are intended for electri-
cians. Please read the instructions carefully
prior to operation and keep them for later
reference.

1 Applications

The LED panel is specially designed for instal-
lation to a ceiling to provide room illumina-
tion. Installation is easy and can be done in
different ways:
1. Installation to suspended ceilings with grid
boards (OWA ceiling grid): Simply insert
the panels.
2. Installation to suspended ceilings without
grid boards: The required mounting frames
are available as options (please refer to
"Specifications"/"Accessories").
3. Installation by screwing the panels to the
ceiling: The adequate mounting frames are
available as options (please refer to "Spec-
ifications"/ "Accessories")
4. Suspended installation: Use the rope set
LEDP-4SP.
2 Safety Notes
The LED panel corresponds to all relevant
directives of the EU and is therefore marked
with
.
The LED panel is suitable for indoor use
only. Protect it against dripping water,
splash water and high air humidity. The
admissible ambient temperature range is
0 – 40 °C.
Clean the plastic pane of the panel with a
soft cloth, dry or slightly damp. Never use
abrasive detergents or chemicals.
No guarantee claims for the LED panel and
no liability for any resulting personal dam-
age or material damage will be accepted
if the LED panel is used for other purposes
Specifications
Dimensions
Weight
Rated power
Power supply / Power consumption
Luminous flux
Number of LEDs
Energy efficiency class
Lighting colour
Beam angle
Rated life
Dimmable
Accessories (optional)
Mounting frame for
suspended ceilings without grid board
Mounting frame
to be screwed to the ceiling
Rope set for suspended installation
Subject to technical modification.
than originally intended or if it is not cor-
rectly installed or operated.
If the LED panel is to be put out of op-
eration definitively, take it to a local
recycling plant for a disposal which
is not harmful to the environment.
3 Mounting
3.1 Suspended ceiling
with grid boards
LED panels for various grid dimensions are
available. Simply insert the panels into the
grids. Make sure to establish the electrical
connection first.
3.2 Suspended ceiling
without grid boards
To install a panel to a suspended ceiling
without grid boards, use the appropriate
mounting frame (please refer to "Specifica-
tions"/"Accessories").
1) Saw a cutout into the ceiling that matches
the size of the mounting frame.
2) If necessary, ask a second person to hold
the frame in the cutout.
3) Screw the four mounting brackets onto
the frame so that the frame securely fits
into the cutout (fig. 1 on page 2).
4) Establish the electrical connection.
5) Insert the panel into the frame.
3.3 Direct installation at the ceiling
To screw a panel to the ceiling, use the ap-
propriate mounting frame (please refer to
"Specifications"/ "Accessories").
1) Screw the frame components A, B and C
together (fig. 2 on page 2).
2) Screw the assembled frame to the ceiling.
3) Establish the electrical connection.
4) Slide the panel into the frame; then screw
component D onto the frame to close the
frame.
LEDP-300RGB
LEDP-600RGB
295 × 10 × 295 mm
595 × 10 × 595 mm
1.1 kg
3.7 kg
12 W
48 W
24 V (⎓) / 0.5 A
24 V (⎓) / 2 A
230 – 240 lm
950 – 1050 lm
48 × SMD 5050 RGB
216 × SMD 5050 RGB 216 × SMD 5050 RGB 216 × SMD 5050 RGB 216 × SMD 5050 RGB
LEDP-300RGB
LEDP-600RGB
LEDP-300RF
LEDP-600RF
LEDP-300F
LEDP-600F
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.

3.4 Suspended installation

For suspended installation, use rope set LEDP-
4SP. The installation is shown in figure 3 on
page 2.
1) Unscrew the lower part (b) of each rope
support and screw the upper parts (a) to
the ceiling with a corresponding distance
between the parts.
2) Guide a rope through the lower part of
each rope support and through the panel
support hook.
3) Screw the lower part of the rope support
with the rope to the upper part of the rope
support at the ceiling.
4) To adjust the desired length of the four
ropes, press the sleeve (c) of the panel
support hook.
5) Hook the eyebolts of the panel into the
support hook. Then fine-adjust the rope
length to align the panel horizontally.
6) Establish the electrical connection.

3.5 Electrical connection

Connection to the 230 V mains must only
be made by skilled personnel!
Use a suitable PSU (e. g. PSIP-60 / 24 (24 V,
2.5 A) to connect the panel to the 230 V mains.
For panel control, the controller CU-3BT, for
example, can be inserted. The wireless remote
controls CU-1BTT and CU-2BTT can be used
with the CU-3BT.
LEDP-620RGB
LEDP-1230RGB
620 × 10 × 620 mm
295 × 10 × 1195 mm 595 × 10 × 1195 mm
4 kg
48 W
24 V (⎓) / 2 A
24 V (⎓) / 2 A
950 – 1050 lm
950 – 1050 lm
A+
red, green, blue
120°
30 000 h
yes
LEDP-620RGB
LEDP-1230RGB
LEDP-620RF
LEDP-1230RF
LEDP-620F
LEDP-1230F
LEDP-4SP
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
LEDP-1260RGB
4.2 kg
7.4 kg
48 W
48 W
24 V (⎓) / 2 A
950 – 1050 lm
LEDP-1260RGB
LEDP-1260RF
LEDP-1260F