Voltage detection Automatic
Polarity detection Full range
Range detection
Automatic load
(RCD trip test)
Internal load
Current Is
Connectable load
Test current
connectable load
Operation time
(DT)
Recovery time
Automatic power
on
Data Hold
(2100-Beta only)
Overload
indication
(2100-Beta only)
Single Pole Phase Test
Voltage range
Frequency range
Acoustic
indication
LED indication
Continuity Test
Range
Tolerances
Test current
Acoustic
indication
LED indication
Overvoltage
protection
Automatic power
on
Rotary Field Detection
Voltage range
Frequency range
LED indication
General Specifications
Operating
temperature
range
Storage
temperature
range
Humidity
Operating
altitude
Measurement
category
Pollution degree
IP Protection
Safety
regulations
Automatic
Yes
Approximately 2.4 W at 690 V (load
buttons activated)
<3.5 mA at 690 V (load buttons
activated
Approximately 240 W at 690 V
<350 mA
30 s
240 s
>12 V
(activated load buttons)
>24 V
(w/o load buttons)
12...690V AC/DC
≥ 770 V AC/DC, display will show
"OL"
180...690 V AC against earth
40 Hz...70 Hz
yes
Red LED
0....500 kΩ
0% to +50%
<5 μA
yes
Red LED
690 V AC/ DC
< 500 kΩ
340...440 V AC phase to phase
47 Hz...63 Hz
Red LED
-15°C to +55°C
-15°C to +55°C
Max. 95% RH
Up to 2000 m
CAT IV 600V,
CAT III 690V
2
IP 64
EN 61243-3:2010
8