Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded base - connection hoses not completely
Hot water temperature too low
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
screwed into basic body
- O-ring at the connection hose de-
fective.
- Hot water limiter incorrectly set
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 36)
To adjust the hot water limiter on single lever
mixers, please see page 36. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Dimensions (see page 34)
Flow diagram
(see page 34)
Spare parts (see page 38)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Operation (see page 37)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Cleaning
see enclosed brochure
Test certificate (see page 40)
Remedy
- Clean aerator, replace as necessary
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter