TERMINALS of the DRV2
Terminal #
1
2
3
4
5
6
7
8
9
- DC POWER
10
THE 2 LED's AND THEIR SIGNIFICATIONS
Each channel A or B has a set of 2 LED's on the front face. The information's hereunder refer individually
to each channel, i.e. one can be OK and the other one in overload...
LED
Green
Red
1.5s ON/0.5s OFF
MC701r-ml-0625
Marking
Description
InA 0-10V
Analogue set point input for channel "A"
0V
0V of the analogue input "A" (Internal limitation to 10V)
InB 0-10V
Analogue set point input for channel "B"
0V
0V of the analogue input "B" (Internal limitation to 10V)
BRK A+
Output channel "A" +
BRK A-
Output channel "A" -
BRK B+
Output channel "B" +
BRK B-
Output channel "B" -
Power supply 24-48VDC -
+ 24-48 V
Power supply 24-48VDC +
Flashing cycles of the LED's
Green
Red
Off
Off
Normal operation
On
Off
Off
Over-excitation operation
On
0.5s ON/1.5s OFF
1s ON/ 1s OFF
On
0.5s ON/2.5s OFF
On
The drive is OFF
The drive is ON, ready
The drive is ON, operating in anti-residual
mode
Drive over excitation possible.
Limitation to 60 s maximum at full voltage
Set point is in over excitation mode, but the
time limit of 60 s is exceeded.
Maximum output voltage limited to 24 VDC
Normal operation, but the over excitation is not
possible. The integral U
process to decrease.
Caution: This information disappears if the
system switches to anti-residual mode. The
2
integral U
t still needs to decrease before a
new over-excitation is possible.
USER MANUAL
MCS2000-DRV2 & PSDRV2
2
t is still too high and in
Page 3 of 16