Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Connected products:
The sum of the leakage current of Smart Line and the connected equipment should
not exceed 3,5 mA.
Make sure that the connected load does not exceed the power of Smart Line : to
ensure improved backup time and longer battery life, we recommend a load equivalent
to 1/3 of nominal power.
Do not leave any container with liquid on the UPS or close to it.
Smart Line has been designed for personal computers. It should not be used with
power electronic equipment with inductive loads such as motors or fluorescent lights.
Do not connect any household appliances such as microwave, vacuum cleaner, hair
dryers to Smart Line, or any life-supporting system.
Due to excessive consumption, laser printers should not be connected to the UPS.

About batteries:

Qualified technicians are recommended to change the battery.
Do not dispose of the battery in a fire as it may explode.
Do not open or mutilate the battery. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
Smart Line contains one/two large-capacity batteries. So the shell shall not be
opened, otherwise such dangers as electric shock will be caused. If any overhaul or
replacement of the battery is required, please contact the distributor.
Servicing of batteries should be performed or
knowledgeable of batteries and the required precautions. Keep unauthorized personnel
away from batteries.
A battery can present a risk of electrical shock and high short circuit current. The
following precautions should be observed by a qualified technician when working on
batteries:
1)
Remove watches, rings or other metal objects from the hand.
2)
Use tools with insulated handles.
3)
Disconnect charging source prior to connecting or disconnecting batteries
terminal.
4)
When replacing batteries, replace with the same type and number of the
sealed lead-acid batteries.
4 . S T O R A G E I N S T R U C T I O N S
Smart Line should be stored with its battery fully recharged. If Smart Line has to be stored
for a long time, it is recommended to recharge the batteries (by connecting the utility power
to UPS, switch "ON"), once a month for 24 hours to avoid a full battery discharge.
Infosec UPS System - 4, rue de la Rigotière – 44700 Orvault – FRANCE - www.infosec.fr
Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 03 05 04 206 15
supervised by personnel