ACDelco ARM602-3 Manuel Informations Du Produit page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Height
Accuracy ►CW
Accuracy ►CCW
Operation Range
Setting Range
Resolution
Operation Mode
Power Saving Mode
Operating
Temperature
Storage
Temperature
Battery
Tool Weight 0.31 lbs (0.14kg)
BATTERY INSTALL AND REPLACEMENT
1. Prepare 2 new coin cells of "CR2032".
2. Loosen the 2 screws on the coin cell cover by a screwdriver.
3. Replace the 2 coin cells (with the "+"sign facing upwards).
4. Tighten the screws to fix the cover.
NOTE
1. When cell capacity is low, the digits on the display will be not clear.
2. Remove the coin cells if stored for a long period of time.
3. Keep spare coin cells on hand when going on a long trip or to cold areas.
4. Do not mix the type of coin cells or combine used coin cells with new ones.
1English1
±2% from 20% to 100% of full scale
±3% from 20% to 100% of full scale
59(ft-lb)
708(in-lb)
80(Nm)
816(kg-cm)
5.9-59(ft-lb)
71-708(in-lb)
8-80(Nm)
82-816(kg-cm)
0.1 ft-lb, 1 in-lb, 0.1 N-m, 1 kg-cm
After 60 seconds of No Use
-10~60°C (14~140°F)
Coin Cell (CR2032) x 2
ASSEMBLY
English
1-29/32"(48mm)
147.5(ft-lb)
1770(in-lb)
200(Nm)
2039(kg-cm)
14.8-147.5(ft-lb)
177-1770(in-lb)
20-200(Nm)
204-2039(kg-cm)
Peak / Trace
0~50°C (32~122°F)
0.44 lbs (0.20kg)
-7
250.8(ft-lb)
3009(in-lb)
340(Nm)
3467(kg-cm)
25.1-250.8(ft-lb)
301-3009(in-lb)
34-340(Nm)
347-3467(kg-cm)
0.44 lbs (0.20kg)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Arm602-4Arm602-4a

Table des Matières