UHF Wireless Microphone System
5
Programming
Note
See the frequency overview on the last page
of this manual for the allowed frequency
ranges in your country.
The minimal frequency interval is 125 kHz.
When using multiple wireless microphone
systems close to each other, use a frequency
interval of 250 kHz or more to avoid
interference.
5.1
Receiver
Frequency selection
1 Turn the receiver ON by pressing the POWER
button (1).
2 Turn the handheld microphone ON by switching
the ON/OFF switch on the rear of the microphone
to the ON position. Or turn the belt-pack ON by
setting the switch to the ON position.
3 Press the SET button on the receiver for 2 seconds
to activate the menu. Once FREQ icon is blinking
the frequency can be selected by using the UP and
DOWN button.
4 Press the SET button again to store the selected
frequency.
figure 5.1: Frequency selection
Note
In case the receiver is locked, the settings
can not be changed. For unlock, see
instructions on Lock mode.
Bosch Security Systems B.V.
Note
The receiver automatically selects antenna A
or B, depending on receiving conditions
(diversity).
Frequency scanning
1 Press the SET button on the receiver for 2 seconds
to activate the menu. Do not use the UP or DOWN
button.
2 Press the SET button again and when the SCAN
icon is blinking press the UP or DOWN button to
start scanning. Scan UP or DOWN until the
frequency of the active microphone has been
found.
3 Press the SET button again to store the selected
frequency.
4 Adjust the AF signal by turning the output level
control knob (1) located on the front of the
receiver.
figure 5.2: Frequency scanning
Lock mode
1 Press the UP button for 3 seconds to activate
LOCK ON or LOCK OFF.
1
Note
In case the LOCK mode is ON, the receiver
cannot be switched OFF.
1
IUI-MW1-XXX | V2.0 | 2012.11