Télécharger Imprimer la page

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5

Liens rapides

USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING
MODE D'EMPLOI / MANUAL DE UTILIZACION / INSTRUZIONI PER L'USO
AGM BATTERY
55Ah / 70Ah / 90Ah / 130Ah / 160Ah / 225Ah / 270Ah
MASTERVOLT
Snijdersbergweg 93, 1105 AN Amsterdam
The Netherlands
Tel.: +31-20-342 21 00
Fax.: +31-20-697 10 06
www.mastervolt.com
10000010148/07

Publicité

loading

Sommaire des Matières pour Mastervolt AGM-55Ah

  • Page 1 USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING MODE D’EMPLOI / MANUAL DE UTILIZACION / INSTRUZIONI PER L’USO AGM BATTERY 55Ah / 70Ah / 90Ah / 130Ah / 160Ah / 225Ah / 270Ah MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-342 21 00 Fax.: +31-20-697 10 06...
  • Page 2 General Charging Mastervolt AGM batteries are immediate ready for use. Use only chargers with IUoUo characteristic. Voltage settings: float charge 13.80V @ 25ºC / 77ºF; Installation absorption charge 14.25V @ 25ºC / 77ºF (max 5 hrs).
  • Page 3 Laden Algemeen Gebruik uitsluitend laders met IUoUo karakteristiek, Mastervolt AGM accu’s zijn direct klaar voor gebruik. ingesteld op de volgende laadspanningen: floatspanning Installatie 13.80V @ 25ºC; absorptiespanning 14.25V @ 25ºC • Controleer de accu vóór installatie op mechanische (max.
  • Page 4 Wasser auswaschen. Armbänder usw. Laden Allgemein Verwenden Sie nur Ladegeräte mit IUoUo Merkmal. Mastervolt AGM-Batterien sind sofort einsatzbereit. Spannungseinstellungen: Erhaltungsladung 13,80V @ Installation 25ºC; Ausgleichsladung 14,25V @ 25ºC (max. 5 Stun- • Prüfen Sie die Batterie vor der Installation auf den).
  • Page 5 Informations générales Charge Les batteries AGM Mastervolt sont livrées prêtes à N'utiliser que des chargeurs ayant la caractéristique l'emploi. IUoUo. Réglages de la tension : charge d'entretien 13,80V @ 25ºC / 77ºF ; charge d'absorption 14,25V @ Installation 25ºC / 77ºF (5 heures maximum).
  • Page 6 25 ºC / 77 ºF; carga de absorción 14,25 V @ 25 ºC / 77 General ºF (máx. 5 h). Se recomienda una carga de temperatura Las baterías Mastervolt AGM están listas para su uso compensada (–30 mV / ºC o –17 mV/ ºF). inmediato.
  • Page 7 Indicazioni generali Carica Le batterie AGM della Mastervolt sono immediatamente Usare solo caricabatterie con caratteristica IUoUo. pronte per l’uso. Impostazioni della tensione: carica oscillante 1,.80 V @ 25ºC; carica di assorbimento 14,25 V @ 25ºC (max 5 Montaggio ore).
  • Page 8 INSTALLATION 1: SERIAL CONNECTION Serieschakeling Serial connection Reihenschaltung Connexion en serie 90Ah 90Ah 90Ah Conexión en serie Collegemento in serie 90Ah 90Ah 90Ah 24V /90Ah 48V /90Ah Figure 1 – Figuur 1 – Abbildung 1 Figure 2 – Figuur 2 – Abbildung 2 Figure 1 –...
  • Page 9 Figure 7 - Figuur 7 - Abbilding 7 - Figura 7 Figure 6 - Figuur 6 - Abbilding 6 - Figura 6 RATED CAPACITY Rated capacity @25ºC/77ºF Capacity affected by temperature: Model AGM-55Ah Temperature: Capacity 55Ah 51Ah 44Ah 39.9Ah 30.6Ah AGM-70Ah 70.6Ah...
  • Page 10: Battery Storage

    1260A 1530A CONSTANT CURRENT DISCHARGE (AMPS @25ºC/77ºF) Time (minutes) 1200 Final voltage (V) 10.0 10.2 10.5 10.5 10.5 10.5 10.8 10.8 10.8 AGM-55Ah 132.5 99.7 82.2 55.0 43.7 31.2 18.0 13.4 10.7 AGM-70Ah 162.5 123.5 97.5 78.8 52.0 39.0 22.8 16.9...
  • Page 11: Dimensions

    DIMENSIONS Not to scale! / Niet op schaal!/ Nicht massstaeblich / Sans échelle précise / Senza scala definita Dimensions in mm. See www.mastervolt.com/batteries for detailed drawings Battery casing material: ABS AGM 70Ah AGM 90Ah 62000700 62000900 AGM 55Ah 62000550 AGM 70Ah...
  • Page 12: Technical Support

    La Mastervolt declina ogni responsabilità per eventuali errori o omissioni nelle istruzioni per l'uso e le conseguenze che ne derivano. Copyright © 2019 Mastervolt. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission of Mastervolt is prohibited.

Ce manuel est également adapté pour:

Agm-70ahAgm-90ahAgm-130ahAgm-160ahAgm-225ahAgm-270ah