7.3 Connection of the cables
7.3.1 Product opening
To open the explosion-proof box, consult
the relevant use instructions.
Once the cover is removed, you can access the
connectors board equipped with removable
connectors and a switchboard with three RJ45
connectors and a SFP slot.
7.3.2 Cable entry
Consult the use instructions of the
explosion-proof box.
The box is equipped with holes to host the cable
glands or conduit. Consult the technical drawings for
their type, quantity and arrangement (14 Technical
drawings, page 18).
7.3.3 Connector board description
BOARD DESCRIPTION
Connector Function
J1
Main power supply line
F1
Main power supply fuse
J6
Power supply output
24Vac
J7
Power supply output
24Vac
J8
24Vac output and auxi-
liary contact input
J9
24Vac output and auxi-
liary contact input
F2
24Vac power supply
output fuse
J22
BNC (Video 1) IN
J23
BNC (Video 1) OUT
J26
BNC (Video 2) IN
J27
BNC (Video 2) OUT
J24
8-pole connector IN
J25
8-pole connector OUT
J10
10-pole connector IN
J11
10-pole connector OUT
Tab. 1
10
Terminals - Nominal
section of the cables
used
from 0.2mm (24AWG) up
to 2.5mm (13AWG)
–
from 0.2mm (24AWG) up
to 2.5mm (13AWG)
from 0.2mm (24AWG) up
to 2.5mm (13AWG)
from 0.2mm (24AWG) up
to 2.5mm (13AWG)
from 0.2mm (24AWG) up
to 2.5mm (13AWG)
–
–
–
–
–
from 0.2mm (24AWG) up
to 1.0mm (17AWG)
from 0.2mm (24AWG) up
to 1.0mm (17AWG)
from 0.2mm (24AWG) up
to 1.0mm (17AWG)
from 0.2mm (24AWG) up
to 1.0mm (17AWG)
Stripping length of conductors: 5mm
(0.19in).
J26-J27 J25
J8
J7
J9
J6
J22-
J23
J1
Fig. 3
J11
F1
MNVCMBA_1908_EN
J24
J10
F2