Wall Mounting; Room Ventilation - Riello ACQUAFUN2 11 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
1
Release hood
2
Flue gas release safety device
3
Thermostat 85 °C
4
Heat exchanger
5
Ignition electrode
6
Burner
7
Collector (injector)
2. INSTALLATION
2.a Regulations
The use of gas appliances is subject to strict regulations. It is
therefore important that the UNI 7129 standard is observed.
For liquefied petroleum gas (LPG), the installation must comply
with the requirements of the distributing companies and with the
requirements of the UNI 7131 standard.
2.b Wall mounting
Warning
Do not install this device in an area that contains dust, greasy
vapour and/or corrosive elements.
- The device must be installed on a suitable wall surface in proximity
to a fume disposal flue.
- It is vital to leave the minimal distances around the device as
shown in fig. 3 to allow for maintenance operations to take place.
50
fig. 3
Location
- The water heater must not be tightly placed in an enclosure or
slot, it should have an adequate flow of air around it (fig. 3).
- The water heater must not be placed above a kitchen or other
cooking devices that might deposit grease vapour on its exterior
leading to corrosion.
- Surfaces that sensitive to heat (e.g. wood) must be protected
using appropriate insulation.
- Fig. 4 displays the dimensions necessary for wall mounting.
11 litres
8
Electronic device
9
Water temperature selector
10 Hydraulic valve
11 Cold water inlet
12 Gas
13 Batteries box
50
200
14 Hot water outlet
15 Temperature sensor
16 Gas valve
17 Economiser/Ignition-Off
18 Micro-switch
19 Pilot burner
bracket
210
161
3 x Ø 10mm
11 litres
I
2.c Room ventilation
The installation of the water heater must comply with regulations in
force including any updates. See paragraph 2.a.
Warning: This device can only be installed in venues that are
permanently ventilated according to regulation in force.
14 litres
11
I
161
L
160
M
592
Dimensions in mm
14 litres
I
fig. 4
ENGLISH
fig. 2
14
161
160
637
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Acquafun2 14